Enhanced detection of trace sulfur levels in gasoline by bismuth electrode using square wave voltammetry

Soratape Somsong,Virender K. Sharma,Ibrahim A. Darwish,Waleed Alahmad,Charoenkwan Kraiya
DOI: https://doi.org/10.1080/17415993.2024.2350399
2024-05-09
Journal of Sulfur Chemistry
Abstract:This study introduces a simple, cost-effective, and rapid bismuth electrode-square-wave voltammetry method for determining the total sulfur content in automotive gasoline. Optimal conditions for the developed electrode, including various Bi ion concentrations, deposition times, and potentials, were established on a glassy carbon electrode. The results demonstrated that the highest response was achieved when the bismuth electrode was placed in an acetate buffer and a methanol:toluene (1:1 v/v) solvent. The method was validated with and without a 30-second electro-preconcentration step. The voltammetric method in conjunction with the preconcentration step exhibited a sensitivity of 571.81 nA mg L −1 , a limit of detection (LOD) of 0.02 mg L −1 , and a limit of quantification (LOQ) of 0.08 mg L −1 . Without the preconcentration step, the method yielded a sensitivity of 421.89 nA mg L −1 , an LOD of 0.03 mg L −1 , and an LOQ of 0.11 mg L −1 . The developed method was applied to quantify commercial fuel samples. The results showed that the electrochemical technique yielded a similar total sulfur content to that measured by the standard ASTM D2622 method, with an error of less than 7.5%. Moreover, the method proposed in this study had lower LOD and LOQ limits, meeting the EURO5 and EURO6 regulations.
chemistry, multidisciplinary
What problem does this paper attempt to address?