Steel Finned-Pipe Foundations for Single Pole Structures

Gary J. Reinert,F. Barry Newman,Gary J. Reinert, Sr.
DOI: https://doi.org/10.1061/40642(253)25
2002-08-29
Abstract:Steel finned-pipe foundations have excellent overturning resistance and are especially applicable for support of electric transmission line pole structures having high overturning moment loads. These foundations also have excellent grounding capabilities eliminating the need for supplemental ground rods. SAFE© (SAFE Foundations, Inc.) has developed a procedure for installation of these foundations, which is fast, economical and permits immediate use of the completed foundation. This paper describes the installation procedure, design methods, and full-scale load testing to overturning moments of 2000 kN-m (1500 kip-ft) that demonstrate the usefulness and reliability of this foundation type. The results of three tests are compared with predicted moment capacity by the methods of Broms and Hansen and to predicted moment capacity and deflections using the computer code, COM624, Wang and Reese. For the cases evaluated, the methods by Broms and Hansen tend to overpredict capacity by up to 20%, and COM624 tends to either agree with or underpredict the moment-deflection response.
What problem does this paper attempt to address?