Calibration of the LIGO displacement actuators via laser frequency modulation

E. Goetz,R. L. Savage Jr
DOI: https://doi.org/10.1088/0264-9381/27/21/215001
2010-07-24
Abstract:We present a frequency modulation technique for calibration of the displacement actuators of the LIGO 4-km-long interferometric gravitational-wave detectors. With the interferometer locked in a single-arm configuration, we modulate the frequency of the laser light, creating an effective length variation that we calibrate by measuring the amplitude of the frequency modulation. By simultaneously driving the voice coil actuators that control the length of the arm cavity, we calibrate the voice coil actuation coefficient with an estimated 1-sigma uncertainty of less than one percent. This technique enables a force-free, single-step actuator calibration using a displacement fiducial that is fundamentally different from those employed in other calibration methods.
General Relativity and Quantum Cosmology
What problem does this paper attempt to address?