High Spatial Resolution Thermometer Microprobe Based on the Nitrogen-Vacancy Centers Ensemble in the Diamond Particle With Tapered Fiber

Hui Yang,Guo-Bin Chen,Xu-Tong Zhao,Fei-Yue He,Guan-Xiang Du
DOI: https://doi.org/10.1109/jsen.2023.3325832
IF: 4.3
2023-12-01
IEEE Sensors Journal
Abstract:High-resolution temperature measurement has a wide range of applications in biomedicine, microelectronics, and so on. Diamond particles with nitrogen-vacancy (NV) color centers can be used for high-resolution measurement of physical quantities such as temperature and magnetic field because of their long spin coherence time and wide operating temperature range. In this study, we propose a thermometer microprobe based on diamond particles with NV color centers attached to tapered fibers to sense temperature with high resolution. Due to the difference in crystal strain and surface state characteristics, the temperature dependence of the D parameter (d D/d T) in optically detected magnetic resonance (ODMR) spectra is inconsistent with different NV color center diamond samples. We investigated the influence of laser power (optimal power 13.4 mW) and microwave power (optimal power 20 dBm) on the D parameter and d D/d T(−92.1 kHz/K) to improve the accuracy of the temperature measurement. We also demonstrate temperature sensing of the cooling process and polyimide (PI) film surface using this microprobe and thermocouple (TC). The thermometer microprobe is expected to sense temperature with high spatial resolution in the fields such as integrated circuit (IC) and biology.
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The paper mainly focuses on the development of a high spatial resolution temperature nanoscale thermometer based on the ensemble of nitrogen-vacancy (NV) centers in diamond particles. The research team designed a nanoscale thermometer by attaching diamond particles containing NV centers to the tip of a tapered optical fiber, which enables high-precision temperature measurement. Due to its long spin coherence time and wide operating temperature range, NV centers can be used for high-resolution physical parameter measurements such as temperature and magnetic field. In this study, temperature sensing was achieved by detecting the variation of the D parameter in the optically detected magnetic resonance (ODMR) spectrum. However, the dependence of D parameter on temperature (d D/dT) shows inconsistency among different diamond samples due to differences in lattice strain and surface state characteristics. To improve the accuracy of temperature measurement, the research team investigated the effects of laser power (optimized at 13.4 milliwatts) and microwave power (optimized at 20 dBm) on the D parameter and d D/dT (-92.1 kilohertz per kelvin). In addition, the paper also demonstrated the temperature sensing experiments on the cooling process and the surface of polyimide (PI) film using this nanoscale thermometer. Compared to thermocouples (TC), it showed higher spatial resolution and faster temperature response. The temperature nanoscale thermometer has the potential to achieve high spatial resolution temperature sensing in fields such as integrated circuits (IC) and biology.