Temperature dependence of nitrogen-vacancy center ensembles in diamond based on an optical fiber

Ke-Chen Ouyang,Zheng Wang,Li Xing,Xiao-Juan Feng,Jin-Tao Zhang,Cheng Ren,Xing-Tuan Yang
DOI: https://doi.org/10.48550/arXiv.2111.07585
2021-11-15
Abstract:The nitrogen-vacancy (NV) centers in diamond sensing has been considered to be a promising micro-nano scale thermometer due to its high stability, good temperature resolution and integration. In this work, we fabricated the sensing core by attaching a diamond plate containing NV centers to the section of a cut-off multi-mode fiber. Then we measured the zero-field splitting parameter (D) of NV center ensembles using continuous-wave optical detected magnetic resonance (CW-ODMR) technique. A home-made thermostatic system and two calibrated platinum resistance thermometers were applied for reference temperature measurement. The effects from preparation time and count time in the pulse sequence, laser power, microwave power, and microwave frequency step were investigated. Moreover, the experimental D and T from 298.15 K to 383.15 K was obtained with the standard uncertainty of u(D) = (3.62268~8.54464)x10^-5 GHz and u(T) = (0.013~ 0.311) K. The experimental results are well consistent with the work of Toyli, et al. (Toyli, et al., 2012) using the similar diamond sample. The extrapolation for D-T at 0 K and 700 K also agree with other references, and meanwhile dD/dT varies with temperature. Finally, comparing the D-T relationship measured by different research groups, we can know that the NV concentration resulting in different electron density and manufacturing procedure resulting in different thermal expansion would lead to different D-T relationship. It is worthy to continue further comprehensive research especially from the metrological point of view to develop NV center as a practical and accurate micro-nano scale thermometry.
Applied Physics
What problem does this paper attempt to address?
This paper aims to solve the problem of temperature dependence of nitrogen - vacancy (NV) centers in diamond, especially in fiber - based NV - center ensembles. Specifically, the researchers attempt to experimentally determine the relationship between the zero - field splitting parameter ($D$) of NV centers and temperature ($T$), and improve the calibration reliability of this relationship. This research is of great significance for developing NV centers as high - precision micro - and nano - scale thermometers. ### Background and Objectives of the Paper Nitrogen - vacancy (NV) centers are considered an ideal choice for micro - and nano - scale temperature measurement due to their high stability, good temperature resolution, and ease of integration. The research team in this paper constructed a fiber - based sensor and adhered a diamond plate containing NV centers to the cross - section of a multimode fiber. They used continuous - wave optically detected magnetic resonance (CW - ODMR) technology to measure the zero - field splitting parameter ($D$) of the NV - center ensemble, and carried out reference temperature measurements with a self - made constant - temperature system and two calibrated platinum resistance thermometers. ### Main Research Contents 1. **Experimental Setup and Measurement Process**: - Constructed a fiber - based sensor to achieve highly reliable temperature measurement. - Used CW - ODMR technology to measure the zero - field splitting parameter ($D$) of NV centers. - Ensured the stability and uniformity of temperature through a self - made constant - temperature system. 2. **Optimization of Experimental Parameters**: - Studied the influence of the preparation time and counting time of the pulse sequence, laser power, microwave power, and microwave frequency step size on the experimental results. - Selected the optimal combination of experimental parameters to improve the stability and accuracy of data. 3. **Data Processing and Analysis**: - Used the InvsPoly function to fit the ODMR spectral lines to represent local strain more effectively. - Conducted multiple heating and cooling experiments in the temperature range from 298.15 K to 383.15 K, and obtained the zero - field splitting parameter ($D$) and its uncertainty at different temperatures. 4. **Results and Discussion**: - The experimental results show that as the temperature increases, the zero - field splitting parameter ($D$) gradually decreases, which is consistent with theoretical predictions. - Through quadratic polynomial fitting, the relationship between $D$ and $T$ was obtained: \[ D = a_0 + a_1T + a_2T^2 \] where $a_0 = 2.87749 \pm 0.00096$ GHz, $a_1 = 2.679 \pm 0.568\times10^{-5}$ GHz/K, $a_2 = -1.7312 \pm 0.0833\times10^{-7}$ GHz/K². - The experimental results were compared with the work of other research groups, and it was found that they were highly consistent with the results of Toyli et al. (2012), but the differences in some temperature ranges may be caused by different NV concentrations and manufacturing processes. ### Conclusion The research team successfully established a fiber - based NV - center temperature sensor, and by optimizing experimental parameters and data processing methods, improved the calibration reliability of the relationship between the zero - field splitting parameter ($D$) and temperature ($T$). The experimental results show that the zero - field splitting parameter ($D$) of NV centers changes with temperature, and this change relationship can be accurately described by a quadratic polynomial. These results provide an important reference for further developing NV centers as high - precision micro - and nano - scale thermometers.