A Miniature Liquid Flowmeter Using All-Fiber Fabry–Perot Cavity for Real-Time Measurement

Haotian Ding,Dongqin Lu,Xiangxu Kong,Junxian Luo,Hanwen Liu,Hongwei Tong,Ye Chen,Fei Xu
DOI: https://doi.org/10.3390/photonics11040354
IF: 2.536
2024-04-13
Photonics
Abstract:A miniature and highly sensitive fiber-optic liquid flowmeter based on Fabry–Perot interferometry (FPI) is proposed and demonstrated for fluid-flow micro-channel testing. The diaphragm deformation and pressure of the proposed sensor for flow rate detection are obtained from numerical and finite element method simulations of the theoretical model. The FPI flowmeter can be applied in real time to measure the ultra-wide dynamic range from 0 mL/min to 90 mL/min, with a response time of hundreds of milliseconds, controlling the flow rate with a resolution of 1.08 mL/min, which is 1.2% of the full scale. The quadratic functional relation between dip wavelength shifts and flow rates is verified by the flow calibration curves of the FPI flowmeter under dynamic pressure conditions. In addition, the effective temperature compensation is realized by connecting an FBG temperature sensor for variable temperature flow detection, and the measured error is reduced by nearly 25-times. The proposed sensor has the potential to measure the liquid flow rate in various applications.
optics
What problem does this paper attempt to address?
The paper aims to address the issue of real-time liquid flow measurement, particularly in fields such as biochemistry, vascular medicine, and pipeline monitoring. Specifically, the paper proposes a miniature optical fiber liquid flow meter based on a Fabry-Perot Interferometer (FPI), characterized by: 1. **High Sensitivity and Fast Response**: The FPI flow meter can respond within a few hundred milliseconds and has an ultra-wide dynamic range measurement capability from 0 mL/min to 90 mL/min, with a resolution of 1.08 mL/min, which is 1.2% of the full scale. 2. **Structural Design**: The sensor is composed of bend-insensitive single-mode fiber (BI-SMF), standard fused silica capillary, and coreless fiber (CF), with a size of only 140 micrometers, making it suitable for use in microchannels. 3. **Temperature Compensation**: Effective temperature compensation is achieved by connecting a Fiber Bragg Grating (FBG) temperature sensor, reducing measurement error by nearly 25 times. 4. **Theoretical and Experimental Validation**: The paper validates the relationship between sensor diaphragm deformation and pressure through numerical simulation and finite element methods, and experimentally verifies the flow calibration curve, demonstrating a quadratic function relationship between wavelength shift and flow rate. In summary, this study proposes a novel miniature optical fiber liquid flow meter aimed at addressing issues such as size limitations, sensitivity to environmental interference, and the impact of temperature changes in existing technologies, thereby achieving more accurate and reliable real-time liquid flow measurement.