Study of the impact of linear coupling on off-axis injection ∗
T. Zhang,X. Huang
2018-01-01
Abstract:The next generation of storage ring light sources will likely operate with high linear coupling, which could potentially prevent the use of off-axis injection as large horizontal oscillation of the injected beam is coupled to the vertical plane. We did experiments on the SPEAR3 storage ring to study how linear coupling impact the dynamic aperture and the off-axis injection efficiency. The results show that the dynamic aperture is significantly reduced and injection efficiency can drop to zero when operated on the coupling resonance. However, with large nonlinear detuning, the dynamic aperture and high injection efficiency can survive with the stored beam at full coupling because the injected beam is shifted away from the coupling resonance. INTRODUCTION In existing 3rd generation light sources, the vertical emittance is typically much smaller than the horizontal emittance, with an emittance ratio below 1%. However, for future diffraction limited storage rings (DLSRs), it is not advisable to maintain the same level of vertical-to-horizontal emittance ratio. This is because the horizontal emittance will already be diffraction-limited and hence there is no need to make vertical emittance any smaller, and small vertical emittance will cause significant intra-beam scattering (IBS) and Touschek beam loss. A round beam with equal horizontal and vertical emittances is usually assumed in DLSR designs, and most designs plan to generate round beams by operating on the linear coupling resonance, with fully coupled horizontal and vertical motion. This would be acceptable if on-axis, swap-out injection [1, 2] will be used. However, for the DLSRs that plan to use the traditional off-axis injection scheme, such as PEP-X [3] and PETRA-IV, large coupling between the two transverse planes could cause injection difficulties. With off-axis injection, the injected beam will have large vertical oscillation amplitude through coupling and the initial horizontal offset and may get lost to the small vertical apertures such as the small-gap insertion devices. Off-axis injection with high coupling has been studied in Refs. [4, 5]. In Ref. [5] it was showed that if the coupling resonance strength is corrected to a low level the injection efficiency does not suffer a loss as the coupling resonance is crossed. To understand the dynamics of beam motion near the coupling resonance and to investigate its potential impact ∗ Work supported by U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-76SF00515 † xiahuang@slac.stanford.edu to off-axis injection, we conducted similar experiments on the SPEAR3 storage ring. In the experiments we changed the strength of the linear difference coupling resonance. At each level we moved the horizontal and vertical tunes toward each other to cross the coupling resonance, which changed the coupling ratio. Dynamic aperture and injection efficiency were measured as the betatron tunes were crossed. In the measurements we also observed safe crossing of the linear coupling resonance (νx = νy for the stored beam) when the coupling strength was corrected. However, the dynamic aperture and injection efficiency suffered significant loss at a point after the crossing, which then recovered as the betatron tunes moved further away. An explanation based on the nonlinear detuning of the injected beam is given for the observation, which may serve as a guide for the design of DLSR lattices with off-axis injection. In the following we will first briefly discuss the theory of beam motion with linear coupling, which is followed by a detailed description of the experiments and a discussion of the results. LINEAR COUPLING MOTION The Hamiltonian for coupled beam motion between the horizontal and vertical planes due to skew quadrupole component, a1 = 1 Bρ dBx dx , is given by H = 1 2 x ′2 + 1 2 y′2 + 1 2 Kx(s)x + 1 2 Ky(s)y − a1(s)xy, (1) where the last term, H1 = −a1(s)xy, can be considered a perturbation to the otherwise uncoupled linear motion. By taking a few canonical transformations toward the action-angle coordinates, (Jx , φx), expanding the perturbation term in Fourier series, and keeping only the term with slow varying phase factor near the linear difference resonance νx − νy = l, we arrive at a new Hamiltonian [6] H̄ = νx Jx + νy Jy + G √ Jx Jy cos(φx − φy + χ − lθ), (2) where θ = s/R, R is the ring radius and Ge = − 1 2π ∮ a1(s) √ βxβye−eds, (3) with Ψ− = ψx − ψy − (νx − νy)θ, ψx,y = ∫ s 0 1 βx,y (s′)ds ′, and βx,y are beta functions. Taking another canonical transformation to the resonant processing frame with the generating function [6] F2(φx, φy, J1, J2) = (φx − φy + χ − lθ)J1 + φy J2 (4) 9th International Particle Accelerator Conference IPAC2018, Vancouver, BC, Canada JACoW Publishing ISBN: 978-3-95450-184-7 doi:10.18429/JACoW-IPAC2018-THPML117 02 Photon Sources and Electron Accelerators A24 Accelerators and Storage Rings, Other THPML117 4943 Co nt en tf ro m th is w or k m ay be us ed un de rt he te rm so ft he CC BY 3. 0 lic en ce (© 20 18 ). A ny di str ib ut io n of th is w or k m us tm ai nt ai n at tri bu tio n to th e au th or (s ), tit le of th e w or k, pu bl ish er ,a nd D O I.