Seismic Performance of hollow section concrete-filled GFRP tubular columns under monotonic loads and cyclic loads

Zi-Ming Yang,Ju Chen
DOI: https://doi.org/10.1016/j.tws.2024.112705
IF: 5.881
2024-11-26
Thin-Walled Structures
Abstract:The experimental investigation and analytical reporting in this paper focus on the behavior of HS-CFGT members, specifically their response to both monotonic loads and cyclic loads. A total of 8 specimens, divided into two groups, each group with 2 kinds in loading type, including 6 columns under cyclic horizontal loads and 2 columns under monotonic lateral loads, were tested. The details of the experimental setups, procedures, significant observations encompassing failure modes, maximum bearing capacities, displacement corresponding to the peak load, load-displacement hysteretic curves, skeleton curves, stiffness degradation curves, and energy dissipation curves and were truthfully reported. The inspection of the experimental data has yielded several important conclusions regarding the effect of column parameters on the behavior of HS-CFGT columns. The most significant finding is that the influence of concrete strength and FRP tube thickness on the seismic performance of HS-CFGT columns is not independent of each other. Furthermore, the findings additionally suggest that HS-CFGT columns made of high-strength concrete demonstrate commendable ductility. The initial flexural stiffness for the preliminary design of HS-CFGT columns is also provided to facilitate the implementation of this innovative technology.
engineering, mechanical,mechanics, civil
What problem does this paper attempt to address?