Design and analysis of PCM integrated solar receiver with double-helical tube structure

Muhammad Anser Bashir,Hafiz Muhammad Ali
DOI: https://doi.org/10.1016/j.est.2024.110872
IF: 9.4
2024-02-16
Journal of Energy Storage
Abstract:The design of working fluid (WF) tubes inside the phase change material (PCM) based thermal storage unit plays a significant role in determining the temperature distribution, as well as the melting and solidification rate of PCM. A uniform temperature inside the PCM volume can be ensured by considering a well distributed WF tubes structure in it. Previous research by authors introduced a PCM integrated tubular solar receiver for small-scale dish-micro gas turbine system. This receiver has U-tubes structure in the PCM volume and features a conical shaped cavity at the receiver aperture. These solar receiver are designed to store short-term (15–20 min) energy in order to mitigate the impact of natural solar fluctuations. In this study, a novel tube structure consisting of double-helical tubes with inlet and outlet sections were utilized in the solar receiver to have better distribution of WF tubes within the PCM volume, resulting in a more uniform temperature distribution. The solar receiver includes six such tubes, wrapped around the conical cavity, with the helix diameter gradually decreasing from the first to the sixth tube while maintaining an equal distance from the cavity wall. Detailed 3D modelling using ANSYS Fluent 2022 R1 was conducted to investigate the behavior and thermal capacity of the storage system. The study commenced with a steady-state charging (melting) phase under a constant solar flux. Subsequently, considering the interruption in solar flux, the transient discharging (solidification) phase was initiated after the steady-state charging phase. The solidification behavior of the PCM and outlet air temperature were analyzed after each time step. The results demonstrated a favorable behavior of the double-helical tube solar receiver, with a PCM liquid fraction of approximately 28 % after 30 mins of discharging phase, while the outlet air temperature at this point reached approximately 1000 K. The outlet air temperature remained stable, decreasing only 50 K during the discharging phase from 7 to 30 min. However, these tubes exhibited a higher pressure drop due to some sharp bends. Furthermore, the temperature distribution on the conical cavity was analyzed.
energy & fuels
What problem does this paper attempt to address?