Direct reconstruction of the effective atomic number of materials by the method of multi-energy radiography

Sergey V. Naydenov,Vladimir D. Ryzhikov,Craig F. Smith
DOI: https://doi.org/10.1016/j.nimb.2003.09.020
2003-10-23
Abstract:A direct method is proposed for reconstruction of the effective atomic number by means of multi-energy radiography of the material. The accuracy of the method is up to 95% . Advantages over conventional radiographic methods, which ensure accuracy of just about 50%, are discussed. A physical model has been constructed, and general expressions have been obtained for description of the effective atomic number in a two-energy monitoring scheme. A universal dependence has been predicted for the effective atomic number as a function of relative (two-energy) radiographic reflex. The established theoretical law is confirmed by the experimental data presented. The proposed development can find multiple applications in non-destructive testing and related fields, including those in the civil sphere as well as anti-terrorist activities.
Accelerator Physics,Medical Physics
What problem does this paper attempt to address?