Cracking of toluene by corona plasma combined with MnO 2 /CeO 2 catalyst loaded on corona anode surface

Wei Ji,Guangfei Qu,Junhong Zhou,Ping Ning,Junyan Li,Huimin Tang,Keheng Pan,Ruosong Xie
DOI: https://doi.org/10.1016/j.seppur.2023.124185
IF: 8.6
2023-06-02
Separation and Purification Technology
Abstract:To solve the problems of complex equipment and low removal efficiency of VOCs with plasma coupled catalysts. In this study, toluene was used as a substitute for VOCs, and MnO 2 /CeO 2 composite catalyst was directly electrodeposited on corona discharge anode to form a catalytic film, and the effective coupling of plasma and catalyst was achieved, which reduced the complexity of the equipment and ensured the high efficiency of toluene cracking. The results show that the oxygen concentration is beneficial to improve the catalytic activity of the catalyst but reduces the corona discharge plasma intensity. When the oxygen content is 5.5% and the voltage is 12 kV, the highest cracked rate of toluene can reach 95%. MnO 2 has strong high voltage resistance and can prolong the effective catalytic time of the catalyst. CeO 2 has high catalytic activity, mainly for the complete removal of toluene fragments. When the concentration of Ce 3+ in the electrodeposition solution is 0.02 mol/L and the electrodeposition time of MnO 2 is 60 min, the ratio of MnO 2 to CeO 2 in the MnO 2 /CeO 2 composite catalyst is the best, and the cracked rate of toluene is the best. Finally, the plasma discharge in this system and the mechanism of toluene removal by catalyst coupled plasma are analyzed in detail.
engineering, chemical
What problem does this paper attempt to address?