Fundamental noise limitations to supercontinuum generation in microstructure fiber

K. L. Corwin,N. R. Newbury,J. M. Dudley,S. Coen,S. A. Diddams,K. Weber,R. S. Windeler
DOI: https://doi.org/10.1103/PhysRevLett.90.113904
2002-12-07
Abstract:Broadband noise on supercontinuum spectra generated in microstructure fiber is shown to lead to amplitude fluctuations as large as 50 % for certain input laser pulse parameters. We study this noise using both experimental measurements and numerical simulations with a generalized stochastic nonlinear Schroedinger equation, finding good quantitative agreement over a range of input pulse energies and chirp values. This noise is shown to arise from nonlinear amplification of two quantum noise inputs: the input pulse shot noise and the spontaneous Raman scattering down the fiber.
Optics
What problem does this paper attempt to address?
This paper aims to solve how to design and implement a high - performance Time Projection Chamber (TPC) in the environment of future linear colliders (such as TESLA). Specifically, the paper attempts to solve the following key issues: 1. **High - resolution tracking**: To meet the requirements of physical experiments, the TPC needs to have extremely high momentum resolution ($\delta(1/p_t) < 1.5\times 10^{- 4}/\text{GeV}$) to accurately measure the recoil mass of the Z boson. 2. **Vertex resolution ability**: The TPC needs to have excellent vertex resolution ability in order to identify heavy - flavor particles. 3. **Electromagnetic and hadronic shower reconstruction**: The TPC should be able to reconstruct electromagnetic and hadronic showers with high precision. 4. **Continuous readout and high granularity**: Since there is no dedicated hardware trigger, the TPC must remain active during the entire bunch train, and sufficient granularity is required to resolve the expected number of hits. 5. **Ion feedback suppression**: During the bunch train, positive ions will accumulate in the TPC drift volume, causing distortion of the drift field. Therefore, effective methods are required to suppress ion feedback. 6. **Application of micro - structure gas detectors**: To meet the above challenges, the research team is exploring the use of micro - structure gas detectors (Micro - Pattern Gas Detectors, MPGDs), such as GEM (Gas Electron Multiplier) and MicroMEGAS (Micro - Mesh Gaseous Structure), as readout technologies. ### Specific problems and solutions - **High - resolution tracking**: By optimizing the design parameters of the TPC (such as inner radius, outer radius and total length), ensure that about 200 spatial points are measured within a large volume, thereby achieving a global tracking efficiency close to 100% and high momentum resolution. - **Ion feedback suppression**: Research shows that using GEM or MicroMEGAS can significantly reduce ion feedback and suppress the feedback to the $10^{-2}$ level. However, in order to ensure that the positive - ion effect is at an acceptable level, further research is still needed to reach the $10^{-4}$ suppression level. If this goal cannot be achieved, it may be necessary to introduce a gating plane to minimize the impact of ion feedback. - **Simulation study**: In order to optimize the performance of GEM and MicroMEGAS, extensive simulation studies have been carried out, especially on the charge transport mechanism. These simulations are crucial for determining the optimal operating parameters. - **Pad geometry study**: In order to improve the point resolution, different pad geometries (such as trapezoidal pads) have been studied. Simulation results show that at a smaller drift distance, the point resolution of trapezoidal pads is better than that of rectangular pads. In summary, the main purpose of this paper is to develop a TPC that can operate efficiently in the environment of future linear colliders and solve the related technical challenges.