Abstract:Objective To explore the effect of hemodynamic factors on the pathogenesis and development of intracranial aneurysms. The fluid-structure interaction (FSI) between blood and vessel wall would be considered in the process. Methods  Based on the data of volume CT digital subtraction angiography (VCTDSA) in a patient with intracranial aneurysms, a true 3D model of intracranial aneurysms was obtained by 3D reconstruction and segmentation in the Mimics 10.0 software. The model was induced into ANSYS 14.0 software, and the vessel wall model was constructed based on human physiology. Fluid model and vascular wall model of intracranial aneurysms were calculated and analyzed with fluid-structure interaction using the finite element method. Results In a cardiac cycle, an obvious vortex flow was contantly found inside the aneurysm with low shear stress area at the top and high shear stress area at the neck of aneurysm. There are larger deformation and Von-Mises stress area at the top, body and neck of the aneurysm. Conclusion By fluid-structure coupling numerical simulation to explore the blood flow characteristics and biomechanical properties of the wall of aneurysm, the possible region prone to rupture may be speculated, thus the rupture risk of aneurysm may be evaluated. This method can provide a technical support for further research of hemodynamics of intracranial aneurysm. DOI: 10.11855/j.issn.0577-7402.2014.11.09