Establishment of 3D Computational Fluid Dynamic Model of Saccular Intracranial Aneurysm

鲁刚,黄磊,张晓龙,王盛章,万军,洪泳,胡宙,耿道颖,徐伟,徐立权
DOI: https://doi.org/10.3969/j.issn.1006-5741.2009.02.015
2009-01-01
Abstract:Purpose:To explore the establishment of patient-specific 3D computational fluid dynamic model of saccular intracranial aneurysms.Methods:3D model was established from 2 patients with intracranial aneurysms through the rotation DSA,and then it was underwent numerical simulation with finite volume methods.Results:Vortex can be found in the streamline figures in 2 aneurysms.Throughout one cardiac cycle,the maximum wall shear stress around the neck of the aneurysm were 17.08±8.82Pa and 25.22±7.62Pa,and the average wall shear stress were 3.40±2.29Pa and 1.85±1.66Pa.Conclusion:Patient-specific 3D computational fluid dynamic model of intracranial aneurysm can show the hemodynamic features of the parent artery and aneurysms,which can be used for further analysis and research.
What problem does this paper attempt to address?