Examination of Antenna Calibration Methodologies in an Extrapolation Range

Zhong Chen,Yibo Wang,D. Lewis
DOI: https://doi.org/10.23919/eucap53622.2022.9769087
2022-03-27
Abstract:Antenna measurements using an extrapolation range have been used for accurate far-field gain calibrations since the 1970s. It is still considered one of the most accurate methods for obtaining the absolute far-field gain of an antenna. The method is based on curve fitting the scalar antenna responses as a function of separation distance to the generalized transmission equation, which is in the form of a polynomial equation. It is much more common today to use vector network analyzers in an extrapolation range. The vector data provides experimentalists additional processing tools to further improve measurement accuracy and reduce effects from extraneous reflections in the chamber. In this paper, we explore the use of angular spectrum filtering for removing chamber multipath effects from the response data. Specifically, we demonstrate the benefits by applying the technique on a set of measurement data obtained in a $30^{\prime} \mathrm{x}30^{\prime} \mathrm{x}70$ ‘ fully anechoic extrapolation range.
What problem does this paper attempt to address?