Quantification of respiration-induced esophageal tumor motion using fiducial markers and four-dimensional computed tomography

Peng Jin, Maarten CCM Hulshof, Rianne de Jong, Jeanin E van Hooft, Arjan Bel, Tanja Alderliesten
2016-03-01
Abstract:Background and purposeRespiration-induced tumor motion is an important geometrical uncertainty in esophageal cancer radiation therapy. The aim of this study was to quantify this motion using fiducial markers and four-dimensional computed tomography (4DCT).Materials and methodsTwenty esophageal cancer patients underwent endoscopy-guided marker implantation in the tumor volume and 4DCT acquisition. The 4DCT data were sorted into 10 breathing phases and the end-of-inhalation phase was selected as reference. We quantified for each visible marker (n = 60) the motion in each phase and derived the peak-to-peak motion magnitude throughout the breathing cycle. The motion was quantified and analyzed for four different regions and in three orthogonal directions.ResultsThe median(interquartile range) of the peak-to-peak magnitudes of the respiration-induced marker motion (left–right/anterior …