Impact of NICE technology appraisal guidance TA566 on access to cochlear implantation for children using hearing aids in the United Kingdom: a multisite observational study

Catherine F Killan,Derek J Hoare,Douglas E H Hartley,Paige Church,Fay Isherwood,Sophia Nasim,Jason Cropper,Robert Gardner,Karen Willis,Nathan Waite,Lynette Garnett,Sara Morgan,Padraig T Kitterick
DOI: https://doi.org/10.1136/archdischild-2023-326055
2024-07-19
Archives of Disease in Childhood
Abstract:Early intervention is essential for deaf and hard-of-hearing children's oral/aural language development. For sensorineural hearing loss, devices include acoustic hearing aids (HAs) and cochlear implants (CIs). Access to CIs in the UK is subject to technology appraisal (TA). The TA audiometric criterion defines which children are referred from HA to CI services for candidacy assessment and influences candidacy. TA166 required unaided air-conduction hearing threshold levels (HTLs) of ≥90 dB HL at 2 kHz and 4 kHz bilaterally.1 TA566 expanded this to at least two HTLs of ≥80 dB HL bilaterally, including 0.5, 1, 2, 3 and 4 kHz.2 We assessed how TA566 changed children's eligibility for CI referral using four hospitals' paediatric HA caseloads (Bradford, Huddersfield, Calderdale and Nottingham). Non-identifiable routine audiology data were collected during 2019–2021. Included cases were <18 years old and prescribed at least one HA but no CI. Bone conduction aid (BCA) users were excluded...
pediatrics
What problem does this paper attempt to address?