Abstract:Background The learning curve effect of dynamic computer‐assisted implant surgery (D‐CAIS) was observed among inexperienced novice surgeons. The learning curves can provide valuable information for novice surgeons and valid comparisons between new and conventional techniques. Recently, robotic computer‐assisted implant surgery (R‐CAIS) has shown promise as a novel dental implant surgical technique for both partially and edentulous patients. However, its learning curve remains unknown. Purpose The aim of this study was to explore the learning curve of dental implant placement surgery with a task‐autonomous robotic system among young dentists with different specialties. Methods and Materials Four young dentists (mean age: 25.3 ± 1.5 years at the beginning of their first attempt) with equal representation of males and females and with different specialties participated in this study. None of the participants had prior experience in R‐CAIS. Each operator placed eight implants over eight attempts using a semi‐active task‐autonomous robotic system. Among the eight implants, four were straight lateral incisor implants, and four were 30°‐tilted premolar implants. The implants were placed in each dental quadrant of the maxillary and mandibular jaw modules. The operation time was recorded. Coronal, apical, and angular deviations between the planned and actual sites of implant placement were measured by merging preoperative and postoperative cone‐beam computed tomography (CBCT) scans. The data were analyzed with repeated‐measures ANOVA (α = 0.05). Results The mean time for implant placement was associated with the number of attempts (p 0.59) nor the tilt angle of the implant (straight or 30°‐tilted, p > 0.85) was related to implant placement accuracy. Conclusions Dentists quickly learned the basic workflow of R‐CAIS and thus facilitated the clinicians in the mastery of implant placement on edentulous jaw modules, leading to a comparable operating speed and high precision. Moreover, the accuracy of placement of straight and tilted implants in both the maxilla and mandible with R‐CAIS was satisfactory.
dentistry, oral surgery & medicine
What problem does this paper attempt to address?