Flexible Textile Sensors-Based Smart T-Shirt for Respiratory Monitoring: Design, Development, and Preliminary Validation

Chiara Romano,Daniela Lo Presti,Sergio Silvestri,Emiliano Schena,Carlo Massaroni
DOI: https://doi.org/10.3390/s24062018
IF: 3.9
2024-03-22
Sensors
Abstract:Respiratory rate () monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected. Additionally, sensor metrological characterization after sensor integration is often omitted. In this study, we present the design, development, and feasibility assessment of a smart t-shirt embedded with two flexible sensors for monitoring. Guided by a motion capture system, optimal sensor design and position on the chest wall were defined, considering both signal magnitude and quality. The sensors were developed, embedded into the wearable system, and metrologically characterized, demonstrating a remarkable response to both static (sensitivity 9.4 and 9.1for sensor A and sensor B, respectively) and cyclic loads (min. hysteresis span 20.4% at 36 bpm obtained for sensor A). The feasibility of the wearable system was assessed on healthy volunteers both under static and dynamic conditions (such as running, walking, and climbing stairs). A mean absolute error of 0.32 bpm was obtained by averaging all subjects and tests using the combination of the two sensors. This value was lower than that obtained using both sensor A (0.53 bpm) and sensor B (0.78 bpm) individually. Our study highlights the importance of signal amplitude and quality in optimal sensor placement evaluation, as well as the characterization of the embedded sensors for metrological assessment.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
This paper aims to address how to achieve effective respiratory monitoring through optimized design and placement of flexible textile sensors. In this study, the authors developed a smart T-shirt embedded with two flexible sensors for monitoring breathing rate. They determined the ideal design and placement of the sensors on the chest wall using a motion capture system, considering both signal amplitude and quality. The sensors were integrated into a wearable system and underwent metrological characterization, demonstrating good response to static and cyclic loads. Preliminary validation experiments conducted on healthy volunteers showed that the combined average absolute error of the two sensors was 0.32 bpm, outperforming a single sensor. The research highlights the importance of evaluating signal quality and sensor placement, as well as the metrological characterization of integrated sensors. Overall, the paper addresses how to achieve accurate and interference-free respiratory rate monitoring through optimized wearable devices.