An accurate respiratory rate estimation algorithm for a rubber fiber respiratory sensor

Ji-seon Kim,Jooyong Kim
DOI: https://doi.org/10.1177/15280837241248181
2024-06-19
Journal of Industrial Textiles
Abstract:Journal of Industrial Textiles, Volume 54, Issue , January-December 2024. Respiratory measurement is a crucial indicator for assessing health status; however, current methods for measuring respiratory rate and frequency are passive and not intuitive. This study investigates peak detection algorithms using a resistive strain sensor integrated into a garment for respiratory rate monitoring. The sensor, constructed with CNT material and a flexible rubber substrate, exhibits high conformity to the body's contours. Designed for respiration measurement, the sensor maintains a low 6% strain for optimal sensitivity, demonstrating a 4% decrease after 800 repetitions of 10% elongation. Garment design emphasizes cohesion between the sensor and fabric, achieved through a piping technique. Respiratory measurement relies on a resistive sensor principle, where abdominal volume changes induce tension, altering resistance. Three peak detection algorithms are evaluated: the window size algorithm, low-pass filter, and FIR filter. The window size algorithm shows a 93% matching rate for normal breathing but requires manual adjustments based on breathing speed. The low-pass filter reduces noise but introduces lag, challenging peak matching. The FIR filter effectively detects peaks at increased speeds, achieving a matching rate exceeding 98%. The study concludes that the choice of algorithm depends on respiratory scenarios, with the window size algorithm suitable for regular cycles, the low-pass filter for real-time monitoring, and the FIR filter for accelerated respiratory rates. The study primarily explores static situations, indicating the need for future research on dynamic respiratory movements to enhance algorithm versatility.
materials science, textiles
What problem does this paper attempt to address?