Instability behavior of bubble supported organic liquid membrane in extraction of low-concentration rare earths from in-situ leaching solutions of ion-adsorption ores

Jie Liu,Xiaohong Wu,Kun Huang,Wenqian Liu,Zhenmin Zhao,Huizhou Liu
DOI: https://doi.org/10.1016/j.mineng.2020.106645
IF: 5.479
2020-12-01
Minerals Engineering
Abstract:<p>Gas bubble supported organic extractant liquid membrane exhibits a promising potential in enhanced extraction and separation of low-concentration rare earths from the in-situ leaching solutions of ion-adsorption ores. However, instability of organic liquid membrane on the surface of gas bubbles might result in dissolution loss of organic extractant in the flowing-out aqueous raffinates and bring serious organic pollution if the raffinates are recycled for re-leaching of rare-earth ores. The present work focuses on the mechanism of the instability of organic extractant P507 liquid membrane on the surface of bubbles during rare-earth extraction. Various effects, including volume flow rate of aqueous feed solution, initial aqueous pHs and concentrations of co-existing impurity ions, saponification degree of P507 and pre-loaded concentration of rare earths in organic phase, on the stability of organic liquid membrane are discussed. Experimental results reveal that the stability of organic liquid membrane depends on three kinds of forces exerting on the surface of bubbles, <em>i.e.,</em> the shear force <em>F<sub>s</sub></em>, the interface tension <em>F<sub>t</sub></em> and the dispersion force <em>F<sub>d</sub></em>. The occurrence of <em>F<sub>t</sub></em> and <em>F<sub>d</sub></em> are benefit for the stability, but <em>F<sub>s</sub></em> is not. The competition of the two component forces of <em>F<sub>s</sub></em> respectively with <em>F<sub>t</sub></em> and <em>F<sub>d</sub></em> will result in instability of organic liquid membrane and an increase in the concentration of total organic phosphorus in the flowing-out raffinates. The present work provides a theoretical basis about how to control the stability of organic extractant liquid membrane on the surface of gas bubble. Based on the suggested new technique by bubble supported organic liquid membrane extraction, a green and environmentally friendly strategy is suggested for replacing the traditional ammonium bicarbonate precipitation to extract low-concentration rare earths from in-situ leaching solutions of ion-adsorption ores.</p>
engineering, chemical,mining & mineral processing,mineralogy
What problem does this paper attempt to address?
The paper attempts to address the issue of the stability of gas bubble supported organic liquid membranes in the process of extracting low-concentration rare earth elements. Specifically, the paper focuses on how to prevent the instability of the organic liquid membrane on the surface of gas bubbles, which can lead to the dissolution loss of the organic extractant into the effluent aqueous phase, causing severe organic pollution. If these aqueous phases containing organic extractants are recycled for re-leaching rare earth ores, it may pose potential environmental risks. ### Background 1. **Environmental Issues of Traditional Methods**: - The method of in-situ leaching with ammonium sulfate and precipitation with ammonium bicarbonate, although widely used in industry, causes serious environmental pollution issues, such as ammonia nitrogen polluting groundwater and soil. - Non-ammonium salt leaching methods (such as aluminum salts, citrate salts, magnesium salts, etc.) can reduce ammonia nitrogen pollution but also have other issues, such as increased costs and new environmental pollution. 2. **Advantages and Challenges of Solvent Extraction**: - Solvent extraction has advantages in separating rare earth elements, effectively avoiding interference from impurities. - Traditional liquid-liquid extraction equipment (such as mixer-settlers, extraction columns or towers, centrifugal extractors) is not suitable for handling low-concentration rare earth element in-situ leachates because it is difficult to avoid emulsification and the loss of organic extractants. ### Research Objectives - **Mechanism Study**: Investigate the instability mechanism of gas bubble supported organic liquid membranes in the process of extracting low-concentration rare earth elements. - **Stability Control**: Through experimental studies, explore the effects of different factors (such as aqueous phase flow rate, initial aqueous phase pH, concentration of coexisting impurity ions, saponification degree of P507, pre-loaded rare earth concentration, etc.) on the stability of the organic liquid membrane, and propose strategies to control the stability of the organic liquid membrane. - **Environmental Alternative**: Based on the gas bubble supported organic liquid membrane extraction technology, propose a green and environmentally friendly alternative to the traditional ammonium bicarbonate precipitation method for extracting low-concentration rare earth elements from in-situ leachates of ion-adsorption type rare earth ores. ### Experimental Design - **Experimental Materials**: Use 2-ethylhexyl phosphonic acid mono(2-ethylhexyl) ester (P507) as the organic extractant and kerosene as the diluent to prepare a 1.5 mol/L P507 organic solution. - **Experimental Steps**: Conduct gas bubble supported organic liquid membrane extraction experiments in a model extraction column. By adjusting different parameters (such as aqueous phase flow rate, initial pH, etc.), observe the stability of the organic liquid membrane and measure the concentration of total dissolved phosphorus in the effluent. ### Results and Discussion - **Effect of Aqueous Phase Flow Rate**: The aqueous phase flow rate has a significant impact on the stability of the organic liquid membrane. When the aqueous phase flow rate is low, the organic liquid membrane is relatively stable; as the flow rate increases, the organic liquid membrane becomes unstable, leading to an increase in the dissolution loss of the P507 extractant. - **Mechanism of Forces**: During the rise of organic bubbles, the main forces acting on the organic liquid membrane include shear force (Fs), interfacial tension (Ft), and dispersion force (Fd). Among them, the two components of shear force (F1 and F2) are detrimental to the stability of the organic liquid membrane, while interfacial tension and dispersion force are beneficial to stability. - **Stability Control Strategies**: By optimizing parameters such as aqueous phase flow rate, initial pH, and saponification degree of P507, the stability of the organic liquid membrane can be effectively improved, reducing the dissolution loss of the P507 extractant. In summary, this paper aims to propose effective control strategies through in-depth research on the instability mechanism of gas bubble supported organic liquid membranes, to achieve efficient and environmentally friendly extraction of low-concentration rare earth elements from in-situ leachates of ion-adsorption type rare earth ores.