Nondestructive Measurement Technique for Substandard Amoxicillin Based on Thermal Approach

Decho Surangsrirat,Onsiri Srikun,Chaksawat Sangawitayakorn,Titasmith Wannasetdecho,Mananya Puanglamjeak,Prab Birdi,Joe Kirkup,Kam Chana
DOI: https://doi.org/10.1021/acsomega.4c00536
IF: 4.1
2024-05-07
ACS Omega
Abstract:In this study, we introduce a new nondestructive measurement technique based on a thermal approach for the determination of substandard amoxicillin. The quality control of amoxicillin is critical for patient safety, and one of the essential parameters for its evaluation is the content of the active ingredient. Traditional methods for assessing amoxicillin content are defined by their time-consuming nature, reliance on skilled personnel, and frequent necessity for specific reagents. The proposed...
chemistry, multidisciplinary
What problem does this paper attempt to address?