Energy savings evaluation of enhanced classroom daylighting utilization

Yuniar Afifa Nur,Gyuyoung Yoon,Takahiro Sato
DOI: https://doi.org/10.1016/j.enbuild.2024.114179
IF: 7.201
2024-04-17
Energy and Buildings
Abstract:The present research analyzes enhanced classroom daylighting utilization. The enhanced classroom daylighting incorporates a shed roof with an additional ceiling window, where the window-to-wall ratio is 41% on the north face and 56% on the south face. First, daylight factor and daily lighting, heating, and cooling loads were analyzed. In comparison with a typical classroom, an energy-savings effect and maximized energy-savings effect occurred. The result shows that enhanced classroom daylighting is expected to achieve 27% energy savings using daylighting. In addition, compared with the typical model, the energy savings in the enhanced classroom daylighting utilization model could be 10 points higher and is expected to increase by a higher illuminance setpoint. In the last section, a sensitivity study was performed to analyze the relationship between the system operation and the energy consumption ratio. With different ranges and setpoints, the enhanced daylighting utilization model shows a varying tendency with respect to the energy consumption ratio.
energy & fuels,construction & building technology,engineering, civil
What problem does this paper attempt to address?