Lower pressure dripping limits of inclined polyethylene-insulated wires during flame spreading under different oxygen concentrations

Yue Zhang,Jun Fang,Jingwu Wang,Yongming Zhang,Lei Song
DOI: https://doi.org/10.1016/j.firesaf.2020.103108
IF: 3.78
2021-03-01
Fire Safety Journal
Abstract:<p>Understanding the combustion of electric wires at relatively low pressures is very important to establish fire prevention strategies for aircraft and space vehicles. The dripping behaviors of polyethylene (PE)-insulated copper/nichrome wires at lower pressures limits and various inclination angles and oxygen concentrations are investigated in this paper. A theoretical model is developed involving flame growth rate and critical diameter that incorporates the balance between insulation consumption and melting rates, as well as the balance between the gravitational force and surface tension. This study finds that the critical diameter of droplet increases with the increasing inclination angle due to the decreasing receding angle. The pressure limit of the copper core wire is lower than that of nichrome, which results from the lower heat feedback transfer of the copper wire. While the pressure limit at 21% O<sub>2</sub> is higher than that at 30% O<sub>2</sub> owing to the oxygen partial pressure equilibrium. The dripping region of nichrome wire at 30% O<sub>2</sub> is diminished drastically due to the larger consumption rate, while the dripping range of the upward for copper wire is extended due to its larger thermal conductivity.</p>
materials science, multidisciplinary,engineering, civil
What problem does this paper attempt to address?