Effect of different CAD/CAM cutting depths on the post-fatigue load-bearing capacity of novel multilayer zirconia restorations

Xuejing Li,Qiang Wang,Xiaohai Qiu,Baohong Zhao
DOI: https://doi.org/10.1016/j.jdent.2021.103709
IF: 4.991
2021-05-01
Journal of Dentistry
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Objectives</h3><p>To investigate the post-fatigue load-bearing capacity of restorations milled at various cutting depths in a novel strength- and color-gradient multilayer zirconia CAD/CAM disk.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Methods</h3><p>Identical crowns were divided into 4 groups (n=25 per group): crowns milled at 3 CAD/CAM cutting depths in multilayer zirconia disks as 3 experiment groups and homogeneous zirconia crowns as a control group. The color differences between various cutting depths were measured. In each group, crowns were tilted at 15° and subjected to fatigue loading for various numbers of cycles (0, 10<sup>6</sup>, 2 × 10<sup>6</sup>, 3 × 10<sup>6</sup> or 4 × 10<sup>6</sup>, n=5 per subgroup). All surviving crowns were subsequently submitted to a static fracture test to determine load-bearing capacity. The data were analyzed by ANOVA and Weibull distribution analysis. Failure modes were observed with SEM.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>For a novel multilayer zirconia, a deeper CAD/CAM cutting depth corresponded to a higher load-bearing capacity but a darker color. After 10<sup>6</sup> cycles of fatigue loading, there was not a significant reduction in fracture load. However, after 4 × 10<sup>6</sup> cycles, the load-bearing capacity of all crowns decreased significantly by approximately 50%. For multilayer and homogeneous zirconia materials, similar failure mode and Weibull modulus were identified.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusions</h3><p>Restorations can be milled at various CAD/CAM cutting depths in a novel multilayer zirconia disk depending on the durability and aesthetic requirements. The load-bearing capacity of multilayer restorations degraded significantly <u>after 4 × 10</u><sup>6</sup> <u>cycles of fatigue loading, but not after 10</u><sup>6</sup> <u>cycles</u>.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Clinical Significance</h3><p>For a novel multilayer zirconia disk, a posterior restoration can be milled from the middle or bottom of the disk to improve its load-bearing capacity. For an anterior restoration, to meet the aesthetic requirements, milling the entire thickness of a multilayer disk is recommended.</p>
dentistry, oral surgery & medicine
What problem does this paper attempt to address?