Usefulness of a novel narrow-diameter endoscope for endoscopic balloon dilation of esophageal strictures

Koichi Soga,Toshikuni Suda,Ikuhiro Kobori,Yasumi Katayama,Masaya Tamano
DOI: https://doi.org/10.1055/a-2223-4325
2024-01-10
Endoscopy
Abstract:Esophageal stricture is a narrowing of the esophageal lumen, often causing esophageal obstruction [1] [2]. Dilation of strictures by endoscopy using balloon dilation is indicated to restore the patency of the esophageal lumen [3]. We present the case of a 55-year-old Japanese man who presented with chest discomfort. Upper gastrointestinal endoscopy (UGE) revealed a full-circumferential ulcer in the mid-portion of the esophagus, without obvious dysmorphic epithelium ([Fig. 1]). In the absence of obvious malignancy on biopsy, proton pump inhibitors (PPI) were prescribed for severe reflex esophagitis. On day 36 of PPI treatment, the patient reported aggravation of esophageal stasis with solid food. On UGE, an esophageal stricture was observed and was treated by endoscopic esophageal dilatation (EED) using a 12-mm-diameter balloon (CRE PRO GI Wireguided Balloon; Boston Scientific, USA). EED needed to be repeated 2 weeks later. On this second occasion, the stricture was assessed using an ordinary 9.8-mm-diameter upper gastrointestinal endoscope (EG-840T; Fujifilm, Japan), as used on the previous occasion. The endoscope could not be passed through the region of stricture due to scarring in the area of the ulcer ([Fig. 2]). Therefore, we selected to use a narrow-diameter, 7.9-mm upper gastrointestinal endoscope (EG-840TP; Fujifilm). Although the narrow-diameter endoscope could not be passed through the region of stenosis, it could be safely inserted into the esophageal inlet, providing a more detailed assessment of the stricture compared to the 9.8-mm diameter endoscope. The narrow-diameter endoscope includes a 3.2-mm hole for endoscopic forceps, which allowed us to perform EED using a 13.5-mm-diameter balloon (CRE PRO GI Wireguided Balloon) without difficulty ([Fig. 3]; [Video 1]). After EED, the endoscope could be passed through the region of stenosis without resistance. Based on our experience, we propose that the novel narrow-diameter endoscope is a potential first-choice endoscope for safe and reliable EED. Endoscopy_UCTN_Code_TTT_1AO_2AH E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/). This section has its own submission website athttps://mc.manuscriptcentral.com/e-videos. Article published online: 09 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
gastroenterology & hepatology,surgery
What problem does this paper attempt to address?