Enterocutaneous fistula closure using a balloon-assisted enteroscope preloaded with an over-the-scope clip – narrowing the gap

Ramzi Mulki,Ali Ahmed,Kondal Kyanam,Shajan Peter
DOI: https://doi.org/10.1055/a-1471-2037
2021-04-28
Endoscopy
Abstract:Enterocutaneous fistulas (ECFs) are abnormal connections between the intestinal tract and the skin. The over-the-scope (OTS) clip system is an effective tool in closing gastrointestinal leaks, perforations, and fistulas [<a href="#JR2353-1">1</a>] [<a href="#JR2353-2">2</a>].A 52-year-old woman with a history of necrotizing pancreatitis presented for evaluation of an iatrogenic ECF. She had undergone a balloon-assisted enteroscopy (BAE)-guided direct percutaneous endoscopic jejunostomy (DPEJ) placement for enteral nutrition in the setting of necrotizing pancreatitis 1 year previously. After the J-tube was removed, the defect had failed to heal and a moderate output ECF had formed. A computed tomography (CT) scan of the abdomen revealed a connection between the jejunum and the skin, consistent with an ECF ([<a href="#FI2353-1">Fig. 1</a>]).An anterograde single-balloon enteroscopy was performed for fistula closure using the EVIS EXERA II (SIF-Q180; Olympus America), which revealed the fistulous tract ([<a href="#FI2353-2">Fig. 2 a</a>]). To confirm the endoscopic finding, a large volume of contrast was injected, and active leakage was noted proximal to the mid-jejunum. The enteroscope was withdrawn and a 12-mm OTS clip device was mounted onto the tip of the single-balloon enteroscope that was preloaded with the overtube ([<a href="#ME2353-1">Video 1</a>]). The enteroscope was advanced to the fistulous tract and adequate closure was achieved ([<a href="#FI2353-2">Fig. 2 b</a>]). A large volume of contrast was again injected after closure, which revealed no evidence of further leakage ([<a href="#FI2353-3">Fig. 3</a>]). At 3 months after closure, the patient reported no further leakage of intestinal contents and her nutritional status had improved.<span class="b">Video 1</span> Closure of an enterocutaneous fistula using a single-balloon enteroscope preloaded with an over-the-scope clip.ECFs have devastating consequences if left untreated. Most case series have reported the safety and efficacy of mounting the OTS clip on an either a gastroscope or colonoscope [<a href="#JR2353-3">3</a>]. The challenges in this case were appropriate selection and mounting of the fitting device onto the enteroscope, being able to safely traverse the small bowel, and achieving good visualization, apposition, and delivery for successful closure. In conclusion, we have demonstrated that an enteroscope-mounted OTS clip placed during BAE is a safe and feasible option for a small-bowel fistula.Endoscopy_UCTN_Code_TTT_1AP_2AD<span class="i">Endoscopy E-Videos</span> is a free access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high<br/>quality video and all contributions are<br/>freely accessible online.<br/><br/>This section has its own submission<br/>website at<br/><a href="https://mc.manuscriptcentral.com/e-videos">https://mc.manuscriptcentral.com/e-videos</a>Publication Date:<br/>28 April 2021 (online)© 2021. Thieme. All rights reserved.Georg Thieme Verlag KG<br/>Rüdigerstraße 14, 70469 Stuttgart, Germany
gastroenterology & hepatology,surgery
What problem does this paper attempt to address?