Graphene-Derivative Coatings for the Prevention of Opacification Due to Calcification of Hydrophilic Intraocular Lenses

Panagiota D. Natsi,Menelaos Kanakis,Labrini Sygellou,Panos S. Gartaganis,Sotirios P. Gartaganis,Petros G. Koutsoukos
DOI: https://doi.org/10.3390/cryst14020150
IF: 2.7
2024-02-01
Crystals
Abstract:The widespread use of hydrophilic intraocular lenses (IOLs) in eye surgery, fabricated by poly-2-(hydroxyethyl methacrylate) (PHEMA), has highlighted their calcification as a serious problem, implying that their surgical explantation is a rather risky process. The field of biomaterials has been developing rapidly in recent years, with research interest turning to the development of novel materials which involve either copolymers of PHEMA or protective functional coatings. Graphene coatings are particularly attractive because of their respective unique properties. In the present work, we present the results of the investigation of the development of graphene coatings on hydrophilic IOLs and their subsequent performance with respect to calcification opacification. Hydrophilic IOLs with a water content of 18% by weight were coated with graphene oxide (GO) by equilibration with GO suspensions in water. The concentrations of the suspensions ranged from 1 × 10−4 to 20 × 10−4% w/v. The GO suspensions were equilibrated with the IOLs for 5 days at a constant temperature, 37 °C, and rotated in 30 mL tubes end over end. This treatment resulted in the formation of a uniform coating of GO on the IOLs verified by scanning electron microscopy (SEM) and other physicochemical methods. The contact angle of the GO-coated IOLs decreased significantly in comparison with the uncoated IOLs. The GO-coated IOLs exhibited a higher tendency to calcify in supersaturated solutions simulating aqueous humor (SAH). The growth rate of hydroxyapatite (Ca5(PO4)3OH, HAP) on GO-coated IOLs was higher in comparison with the respective untreated IOLs. The conversion of the GO coating via a reduction with phenyl hydrazine resulted in the formation of a reduced-graphene (rGO) surface film, as identified by Raman and XPS spectroscopy. The rGO film was hydrophobic (contact angle 100°) and did not calcify in supersaturated calcium phosphate solutions.
materials science, multidisciplinary,crystallography
What problem does this paper attempt to address?
The main aim of this paper is to address the following issues: ### Research Background and Problem Definition - **Problem Statement**: Hydrophilic intraocular lenses (IOLs), especially those made of poly(2-hydroxyethyl methacrylate) (PHEMA), which are widely used in ophthalmic surgeries, tend to undergo calcification after implantation, necessitating high-risk surgical removal. - **Objective**: The researchers aim to develop a novel coating technology to prevent or reduce the clouding of hydrophilic intraocular lenses caused by calcification. ### Solution - **Research Method**: The paper introduces the use of graphene derivative coatings (specifically graphene oxide (GO) and reduced graphene oxide (rGO)) to treat hydrophilic intraocular lenses and evaluates the effectiveness of these coatings in preventing calcification. - **Specific Experiments**: - Equilibrating hydrophilic intraocular lenses (with 18% water content) in graphene oxide suspensions of different concentrations to form a uniform graphene oxide coating on the lens surface. - Using phenylhydrazine chemical reduction to convert graphene oxide into reduced graphene oxide, thereby forming a hydrophobic surface film. - Analyzing the coating characteristics through contact angle measurements and scanning electron microscopy. - Evaluating the anti-calcification ability of the coatings through mineralization experiments in supersaturated solutions of simulated aqueous humor (AH). ### Main Contributions - **Findings**: The paper indicates that untreated hydrophilic intraocular lenses are prone to calcification, whereas lenses treated with graphene oxide coatings show a higher tendency for calcification in supersaturated simulated aqueous humor solutions. In contrast, lenses treated with reduced graphene oxide exhibit hydrophobic surfaces and no calcification was observed. - **Conclusion**: This suggests that using reduced graphene oxide as a coating can effectively prevent the calcification of hydrophilic intraocular lenses, thereby enhancing their long-term stability and biocompatibility. In summary, this research is dedicated to developing a coating technology that can effectively prevent the calcification of hydrophilic intraocular lenses, thereby improving the performance and safety of implantable medical devices.