Polyvinyl Alcohol/Graphene Oxide Interlayer for Enhancing Adhesive Performance of HA Coating on C/C Composites Prepared by Hydrothermal Electrodeposition/Hydrothermal Treatment

Xin-bo Xiong,Chun Liu,Xin-Ye Ni,Cai-qing Liang,Xie-rong Zeng
DOI: https://doi.org/10.1021/acsami.0c17649
2020-12-02
Abstract:Hydroxyapatite (HA) coatings directly deposited by hydrothermal electrochemical technology (HET) onto carbon/carbon (C/C) composites exhibited a catastrophic failure occurring at the interface of the HA and C/C. To overcome this problem, a polyvinyl alcohol (PVA)/graphene oxide (GO) interlayer (P/G interlayer) was applied on the (NH<sub>4</sub>)<sub>2</sub>S<sub>2</sub>O<sub>8</sub>-pretreated C/C substrate (named P/G-C/C) by using a dipping method. Subsequently, a calcium phosphate coating was deposited on P/G-C/C, shortened as M-P/G-C/C, by HET, and then converted into HA coating (abbreviated as HA-P/G-C/C) through posthydrothermal treatment. For comparison, HA coating was prepared onto C/C without a P/G interlayer through the same process, which was denoted as HA-C/C. The composition, microstructure, and morphology of the samples were characterized by X-ray diffractometry (XRD), energy-dispersive spectroscopy (EDS), scanning electron microscopy (SEM), Raman spectra, Fourier transform infrared (FTIR), and X-ray photoelectron spectroscopy (XPS). The adhesive performance of the coatings on C/C was measured by a scratch test. Finally, an in vitro bioactivity of the coatings was evaluated in a simulated body fluid solution at 37 °C. Results showed no apparent differences in the morphology and phase of the posttreated coatings, both of which are composed of a dense structure containing needle-like HA crystals. However, the HA-P/G-C/C sample possessed a higher Ca/P ratio and denser interface, thereby exhibiting higher adhesive performance and better bioactivity. The adhesive strength of the HA-P/G coating was observed at a critical load of 41.04 N, which increased by 29.3% relative to the HA coating. Moreover, the failure site was on the HA-P/G coating rather than at the interface. The enhanced adhesive performance was ascribed to the PVA/GO-repairing pits on C/C and PVA and GO toughening effects on the HA coating. In vitro and in vivo tests revealed no statistical significance for the two HA-coated C/C samples, although the HA-P/G coating exhibited better bioactivity, inducing the growth of bonelike apatite than the HA coating.This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology
What problem does this paper attempt to address?