Flow direction optimizer tuned robust FOPID-(1 + TD) cascade controller for oscillation mitigation in multi-area renewable integrated hybrid power system with hybrid electrical energy storage

Zafar Ayub Ansari,G. Lloyds Raja
DOI: https://doi.org/10.1016/j.est.2024.110616
IF: 9.4
2024-01-28
Journal of Energy Storage
Abstract:The incorporation of renewable energy sources (REs) in modern interconnected power systems (PSs) raises concerns about stability, flexibility, and appropriateness. Furthermore, the stochastic nature of REs, load disruptions, physical constraints and system parameter variations escalate the issue of frequency oscillations in modern PSs. Owing to this, load frequency control (LFC) is vital to providing high quality, reliable and stable power supply. Hence, this study offers a novel fractional-order proportional-integral-derivative (FOPID) cascaded with 1 + tilted-derivative (1 + TD) controller (FOPID-(1 + TD)) for LFC of the multi-area renewable-integrated hybrid power system (RIHPS). The parameters of the proposed controller are optimized using the flow direction algorithm (FDA) with integral time square error (ITSE) as the fitness function. To begin with, thermal systems with/without governor dead band (GDB) nonlinearity are used for the validation of the FDA-tuned FOPID-(1 + TD) control strategy. Then suggested control strategy is further expanded to a challenging RIHPS where the hybrid micro-grid (HμG) is integrated with the utility grid. The HμG contains wind turbine generator (WTG), organic Rankine cycle (ORC) solar thermal power (STP), biodiesel generator (BDG) and hybrid electrical energy storage (HEES). The superiority in dynamic behavior and robustness of the FDA-tuned FOPID-(1 + TD) strategy is vindicated by simulating various practical scenarios such as step and random load variations, fluctuations in REs generation and aberration of ±25 % in PS parameters. The HEES unit which consists of a redox flow battery (RFB) and capacitive energy storage (CES) is included to advance system performance even further by offsetting the load power requirement. With the recommended FOPID-(1 + TD) controller, significant improvement in dynamic performance is obtained at attaining the depletion of 2 % to 90 %, 26 % to 83 % and 50 % to 95 % in settling time, undershoot and overshoot respectively as compared to contemporaries PID, FOPID, TID and PI-PD controllers. Various nonlinear constraints such as thermo-boiler dynamics (TBD), communication time-delay (CT), generation rate constraints (GRC), and GDB are simulated in the specified system employing FDA-tuned FOPID-(1 + TD) to analyze the impact of the same on oscillation mitigation. Finally, the stability of the control system is assessed from Bode plots.
energy & fuels
What problem does this paper attempt to address?