Fractional-Order Load Frequency Control of an Interconnected Power System with a Hydrogen Energy-Storage Unit

Ping Wang,Xi Chen,Yunning Zhang,Lei Zhang,Yuehua Huang
DOI: https://doi.org/10.3390/fractalfract8030126
IF: 3.577
2024-02-22
Fractal and Fractional
Abstract:Modern power systems are confronted with widespread concern on the frequency stability issue due to the widespread integration of randomly fluctuating renewable resources. To address the above concern, this work introduces a load-frequency-control (LFC) scheme based on a parameter tuning strategy for fractional-order proportional–integral–derivative (FOPID) controller. Firstly, a two-area interconnected power system (IPS) model, including thermal, hydro, solar, wind, and gas power generator and a hydrogen-based energy-storage unit, is established. Then, a FOPID controller is designed for this IPS model, and an improved gradient-based optimizer (IGBO) is developed to adaptively regulate the parameters of the FOPID controllers. Finally, the effectiveness of the offered LFC scheme is tested through load disturbance and renewable energy fluctuations test scenarios and provides a comparison and robustness analysis among different schemes. The test results validated that the offered LFC scheme can effectively suppress the frequency fluctuations of the IPS and has excellent robustness.
mathematics, interdisciplinary applications
What problem does this paper attempt to address?
This paper aims to solve the frequency stability problem in modern interconnected power systems (IPS) caused by the integration of a large number of randomly fluctuating renewable energy sources. Specifically, the author proposes a load frequency control (LFC) scheme based on the fractional - order proportional - integral - derivative (FOPID) controller and combines an improved gradient - based optimizer (IGBO) to automatically adjust the parameters of the FOPID controller. By establishing a two - area interconnected power system model including thermal, hydraulic, solar, wind and gas - fired power generation units as well as a hydrogen energy storage unit, the paper designs the FOPID controller and uses the IGBO algorithm for parameter optimization. Finally, the effectiveness and robustness of the proposed LFC scheme are verified through load disturbance and renewable energy fluctuation test scenarios. ### Problems Solved by the Paper 1. **Frequency Stability Problem**: With the integration of a large number of randomly fluctuating renewable energy sources (such as solar and wind energy) into the power grid, the frequency stability of the interconnected power system is challenged. Traditional PID controllers perform poorly in dealing with these nonlinear and uncertain problems, so more advanced control strategies are required to improve the frequency stability of the system. 2. **Parameter Optimization Problem**: Traditional PID controller parameter tuning methods are time - consuming and have limited effectiveness, especially in complex multi - area interconnected power systems. The paper proposes a parameter optimization method based on the IGBO algorithm, which can adaptively adjust the parameters of the FOPID controller, thereby improving the performance and robustness of the system. 3. **Randomness of Renewable Energy**: The output of renewable energy is random and fluctuating, which brings additional challenges to the frequency control of the power system. By introducing a hydrogen energy storage unit, the paper enhances the frequency response ability of the system while considering the random characteristics of renewable energy. ### Main Contributions - **Design of FOPID Controller**: By introducing fractional - order calculus operations, the FOPID controller not only retains the simple structure of the traditional PID controller but also increases the adjustable dimension of the controller parameters, improving the anti - interference ability and robustness of the system. - **Development of IGBO Algorithm**: An improved gradient - based optimizer algorithm is proposed to adaptively adjust the parameters of the FOPID controller, improving the optimization efficiency and accuracy. - **Comprehensive Testing and Analysis**: Through load disturbance and renewable energy fluctuation test scenarios, the effectiveness and robustness of the proposed LFC scheme are verified, and a comparative analysis with other control schemes is carried out. In conclusion, by introducing the FOPID controller and the IGBO algorithm, this paper provides an effective solution to deal with the frequency stability problem brought by the integration of renewable energy in modern interconnected power systems.