Tetrodotoxin Derivatization with a Newly Designed Boron Reagent Leads to Conventional Reversed-Phase Liquid Chromatography

Shimba Kawasue,Kyoko Kuniyoshi,Masashi Uema,Naomasa Oshiro
DOI: https://doi.org/10.3390/toxins16060260
IF: 5.075
2024-06-05
Toxins
Abstract:Tetrodotoxin (TTX) is a representative natural toxin causing pufferfish food poisoning, which is especially prominent in East and Southeast Asia, including Japan. TTX has been analyzed through post-column derivatization high-performance liquid chromatography (HPLC), ion-pair LC-MS(/MS), and hydrophilic interaction liquid chromatography (HILIC)-MS(/MS) as alternatives to the mouse bioassay method. However, post-column derivatization requires a system for online derivatization reactions, and with the ion-pair LC-MS approach, it is difficult to remove residual ion-pair reagents remaining in the equipment. Moreover, HILIC-MS provides poor separation compared to reversed-phase (RP) HPLC and requires a long time to reach equilibration. Therefore, we decided to develop a TTX analytical method using pre-column derivatization and RP HPLC for the rapid assessment of outbreak samples, including food remnants. In this study, we focused on the vic-diol moiety of TTX and designed a new derivatization reagent coded as NBD-H-DAB. This NBD-H-DAB was synthesized from 4-hydrazino-7-nitro-2,1,3-benzoxadiazole (NBD-H) and 3-fluoro-2-formylphenylboronic acid (FFPBA) with a simple reaction system and rapidly converted to its boronate form, coded NBD-H-PBA, in an aqueous reaction solution. The NBD-H-PBA demonstrated appropriate hydrophobicity to be retained on the RP analytical column and successfully detected with a UV spectrometer. It was easily reacted with the vic-diol moiety of TTX (C6 and C11) to synthesized a boronic ester. The derivatized TTX could be detected using the RP HPLC-UV, and the limit of detection in the fish flesh samples was 0.06 mg/kg. This novel pre-column derivatization of TTX with NBD-H-PBA proves capable for the analysis of TTX.
toxicology,food science & technology
What problem does this paper attempt to address?
The problem this paper attempts to address is the development of a new method for detecting tetrodotoxin (TTX). Traditional methods for detecting tetrodotoxin have several issues. For example, the mouse bioassay (MBA) has problems with selectivity, reproducibility, accuracy, and animal welfare; post-column derivatization high-performance liquid chromatography (HPLC) requires specific instrument setups and has troublesome waste disposal; ion-pair LC-MS methods may have ion-pair reagents that remain in the equipment and interfere with other analyses; hydrophilic interaction liquid chromatography (HILIC)-MS methods have poor separation efficiency and are time-consuming. Therefore, researchers designed a new derivatization reagent, NBD-H-DAB, and used reverse-phase high-performance liquid chromatography-ultraviolet detector (RP HPLC-UV) for detection. This method has the advantages of being fast, simple, and not requiring a mass spectrometer or complex post-column derivatization systems.