An alternative method for the rapid verification of the three-dimensional adaptation of splinted implant-supported crowns

Chenyang Xie,Manlin Sun,Zhicheng Yin,Yang Yang,Haiyang Yu
DOI: https://doi.org/10.1016/j.prosdent.2024.10.035
IF: 4.148
2024-11-28
Journal of Prosthetic Dentistry
Abstract:Fit accuracy is crucial for the clinical success of implant-supported prostheses. Traditionally, radiographs have been used to assess the marginal fit in 2 dimensions. Three-dimensional (3D) evaluation based on optical scanning techniques requires additional software programs and procedural steps. This article describes an alternative workflow for the rapid verification of the 3D fit of splinted implant-supported crowns. First, the abutments and splinted crowns were positioned onto a printed cast and scanned, with the data exported as a reference. Following the intraoral placement of the abutments and the splinted crowns, an additional scan was made and compared with the reference data to calculate deviations directly within the intraoral scanner. This protocol simplifies the fit evaluation process and provides rapid results, thereby enhancing efficiency and saving time.
dentistry, oral surgery & medicine
What problem does this paper attempt to address?