Single-Particle Electrochemical Biosensor with DNA Walker Amplification for Ultrasensitive HIV-DNA Counting

Fanwei Luo,Fei Chen,Yi Xiong,Zhen Wu,Xiuhua Zhang,Wei Wen,Shengfu Wang
DOI: https://doi.org/10.1021/acs.analchem.0c04861
IF: 7.4
2021-03-08
Analytical Chemistry
Abstract:Single-particle electrochemical collision has gained great achievements in fundamental research, but it is challenging to use in practice on account of its low collision frequency and the interference of the complex matrix in actual samples. Here, magnetic separation and DNA walker amplification were integrated to build a robust and sensitive single-particle electrochemical biosensor. Magnetic nanobeads (MBs) can specifically capture and separate targets from complex samples, which not only ensures the anti-interference capability of this method but also avoids the aggregation of platinum nanoparticles (Pt NPs) caused by numerous coexisting substances. A low amount of targets can lead to the release of more Pt NPs and the generation of more collision current transients, realizing cyclic amplification. Compared with simple hybridization, a DNA walker can improve the collision frequency by about 3-fold, greatly enhancing detection sensitivity, and a relationship between collision frequency and target concentration is used to realize quantification. The biosensor realized an ultrasensitive detection of 4.86 fM human immunodeficiency virus DNA (HIV-DNA), which is 1–4 orders of magnitude lower than that of traditional methods. The successful HIV-DNA detection in complex systems (serum and urine) demonstrated a great promising application in real samples and in the development of new single-entity biosensors.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.0c04861?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.0c04861</a>.Reagents and instruments (Table S1); preparation diagram of Au UME (Figure S1); calculation of Pt NP concentration (Figure S2); CVs of different Au UMEs before and after being polished (Figure S3); hydrodynamic diameter of Pt NPs (Figure S4); optimization of detection conditions (Figure S5); reusability of Au UME (Figure S6); relationship between collision frequency and Pt NP concentrations (Figure S7); open-circuit potential (OCP) collisions of Pt NPs (Figure S8); characterization of MBs–DNA–Pt NP complexes (Figure S9); specificity of the SPEC biosensor (Figure S10); comparison between the simple base-pairing reaction and DNA walker amplification (Figures S11 and S12); and analytical performance of SPEC for HIV-DNA counting (Figure S13 and Table S2) (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c04861/suppl_file/ac0c04861_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?