Size-Resolved Single Entity Collision Biosensing for Dual Quantification of MicroRNAs in a Single Run

Yi-Yan Bai,Yan-Ju Yang,Zhen Wu,Xiao-Yan Yang,Miao Lin,Dai-Wen Pang,Zhi-Ling Zhang
DOI: https://doi.org/10.1021/acsami.1c04747
2021-05-09
Abstract:Limited to the accuracy of size resolution, single entity collision biosensing (SECBS) for multiplex immunoassays remains challenging, because it is difficult to get the true value of nanoparticle (NP) sizes based on the current intensity due to the complex movement of NPs on the electrode surface. Considering that the size-dependent movement of NPs meanwhile will generate a characteristic current shape, in this work, the huge difference in the current rise time of 5 and 15 nm Pt NPs colliding on an Au ultramicroelectrode (<i>d</i> = 30 μm) was originally used to develop a size-resolved SECBS for multiplex immunoassays of miRNAs. The limit concentration that can be detected was 0.5 fM. Compared with conventional electrochemical biosensors for multiplex immunoassays, for the size-resolved SECBS, one does not need to worry about potential overlapping. Therefore, the proposed method demonstrates a promising potential for the application of SECBS in multiplex immunoassays.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.1c04747?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.1c04747</a>.Characterization of Pt NPs (Figure S1) and Au UME (Figure S2); optimization of the concentration of HClO<sub>4</sub> (Figure S3) and the applied voltage for ECA (Figure S4); quantitative detection of 5 nm Pt NPs (Figures S5) and 15 nm Pt NPs (Figures S6); the blocking effect of the under potential deposition of hydrogen or the generated hydrogen bubble onto the NP surface (Figures S7); comparation of the current intensity and current rise time of 5 and 15 nm Pt NPs (Figure S8 and S9); mixed detection of 2.0 pM 5 nm and 2.0 pM 15 nm Pt NPs (Figure S10); characterization of the MN–DNA–Pt NP conjugates (Figures S11); determination of the concentration of released Pt NPs (Figures S12); details about the nucleotide sequences (Table S1); optimization of the ratio of the concentrations of the two detection probes and the reaction time (Table S2); and comparison of different methods for multiplex immunoassays of miRNAs (Table S3) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.1c04747/suppl_file/am1c04747_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the challenge of simultaneously quantifying multiple microRNAs (miRNAs) in a single run. Specifically, the paper proposes a biosensing method based on Single Entity Collision (SEC), namely SECBS. By taking advantage of the large difference in the current rise time generated when nanoparticles (NPs) of different sizes collide on the electrode surface, it realizes the size - resolved detection of 5 nm and 15 nm platinum nanoparticles (Pt NPs). This method can effectively distinguish nanoparticles of different sizes, thus avoiding the signal overlap problem that traditional electrochemical biosensors may encounter in multiplex immunoassays and improving the accuracy and sensitivity of detection. The paper demonstrates the application potential of this method in multiplex immunoassays, especially for miRNA detection, with a detection limit of up to 0.5 fM. The development of this technology is of great significance for improving the detection efficiency and accuracy of biomarkers.