Experimental Study of White Light Interferometry in Mach–Zehnder Interferometers Based on Standard Single Mode Fiber
José Luis Cano-Perez,Jaime Gutiérrez-Gutiérrez,Christian Perezcampos-Mayoral,Eduardo L. Pérez-Campos,María del Socorro Pina-Canseco,Lorenzo Tepech-Carrillo,Marciano Vargas-Treviño,Erick Israel Guerra-Hernández,Abraham Martínez-Helmes,Julián Moisés Estudillo-Ayala,Juan Manuel Sierra-Hernández,Roberto Rojas-Laguna
DOI: https://doi.org/10.3390/s24103026
IF: 3.9
2024-05-11
Sensors
Abstract:In this work, we experimentally analyzed and demonstrated the performance of an in-line Mach–Zehnder interferometer in the visible region, with an LED light source. The different waist diameter taper and asymmetric core-offset interferometers proposed used a single-mode fiber (SMF). The visibility achieved was V = 0.14 with an FSR of 23 nm for the taper MZI structure and visibilities of V = 0.3, V = 0.27, and V = 0.34 with FSRs of 23 nm, 17 nm, and 8 nm and separation lengths L of 2.5 cm, 4.0 cm, and 5.0 cm between the core-offset structure, respectively. The experimental investigation of the response to the temperature sensor yielded values from 50 °C to 300 °C; the sensitivity obtained was 3.53 a.u./°C, with R2 of 0.99769 and 1% every 1 °C in the transmission. For a range of 50 °C to 150 °C, 20.3 pm/°C with a R2 of 0.96604 was obtained.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation