Partial discharge location algorithm based on total least-squares with Matern kernel in cable systems

Lu Lu,Kai Zhou,Xiaomin Yang,Badong Chen,Zhu Guangya
DOI: https://doi.org/10.1109/tii.2022.3153835
IF: 12.3
2022-01-01
IEEE Transactions on Industrial Informatics
Abstract:Partial discharge (PD) location techniques are a useful tool for condition monitoring of electrical apparatus in power systems. However, the noisy PD measurements may significantly degrade the performance of location algorithms. This article deals with the PD location problem by using adaptive filtering techniques. Heretofore, scarce literature focuses on addressing the PD location based on such method. A novel adaptive algorithm, termed as total least-squares (TLS)-Matrn kernel (TLS-MK), is proposed. Benefiting from the merits of the Matrn kernel, the TLS model can effectively suppress the noise from the direct and reflected waves of the PD source. Meanwhile, the TLS-MK algorithm is used to estimate the time difference, which is used in the PD location. Moreover, the convergence behavior of the TLS-MK algorithm is analyzed. Simulations and experiments show that the proposed algorithm can enhance the location accuracy as compared to state-of-the-art methods for various PD signals.
automation & control systems,computer science, interdisciplinary applications,engineering, industrial
What problem does this paper attempt to address?