Simultaneously Obtaining Stable and Radiogenic Nd Isotope Ratios Through a Single DGA Column Using Double Spike TIMS
Fang Liu,Xin Li,Hong Yang,Qingyao Peng,Jiaojiao Wu,Zhaofeng Zhang
DOI: https://doi.org/10.1039/d3ja00284e
2023-01-01
Journal of Analytical Atomic Spectrometry
Abstract:In this study, we present a high-precision technique for measuring Nd stable isotopes by thermal ionization mass spectrometry (TIMS). A single and efficient Nd separation procedure is adopted with above 99% recovery using the DGA resin (Eichrom, USA). A 145Nd-150Nd double spike (DS) was used to correct mass-dependent fractionation during column chemistry and mass spectrometry. Repeated analyses of the JNdi-1 standard yielded a total average delta 146/144Nd of 0.001 +/- 0.016 parts per thousand (2SD, N = 12), and a delta 148/144Nd of -0.005 +/- 0.045 parts per thousand (2SD, N = 12), respectively. The pure Nd standard, La Jolla, produced a delta 146/144Nd of -0.210 +/- 0.006 parts per thousand (2SE). The delta 146/144Nd of twelve geological reference materials, including COQ-1, DNC-1a, AGV-1, AGV-2, BHVO-2, BCR-2, G-2, RGM-1, GSP-2, NOD-A-1, NOD-P-1, and SDC-1, were also reported. Among them, the delta 146/144Nd of COQ-1 was first reported. Simultaneously, the radiogenic 143Nd/144Nd of reference materials could be calculated using a double spike deconvolution with a precision of <= 5 ppm (2SE), in agreement with published values within an analytical uncertainty measured by conventional methods. Nd isotope fractionation during column chromatography was investigated. The known JNdi-1 was eluted with DGA resin using HCl as a solute and was sequentially collected into 8 fractions. delta 146/144Nd systematically increased from -0.110 +/- 0.011 parts per thousand (2SE) of the first Nd cut to +0.334 +/- 0.011 parts per thousand (2SE) of the tailing cut following the mass-dependent fractionation law, suggesting significant Nd isotope fractionation during column chemistry. This phenomenon contradicts previous observations that light isotopes are preferentially retained onto the resin. The technique established in this study can obtain stable and radiogenic Nd isotopic compositions simultaneously from a single aliquot using a double spike by TIMS, providing at least two-dimensional constrains to the source of a material. In this study, stable and radiogenic Nd isotopic compositions are simultaneously obtained through a single DGA column using a double spike by TIMS. Heavy isotopes are preferentially retained onto the resin, contrary to previous observations.