Battery Internal Short Circuit Detection

Mingxuan Zhang,Minggao Ouyang,Languang Lu,Xiangming He,Xuning Feng,Lishuo Liu,Xiaoyi Xie
DOI: https://doi.org/10.1149/07711.0217ecst
2017-07-07
ECS Transactions
Abstract:Internal short circuit (ISCr) is one of the major obstacles that impede the improvement of the battery safety. In this work, a new ISCr detection method based on the symmetrical loop circuit topology (SLCT) for the battery pack is introduced. The SLCT ensures every battery has the same weight in the circuit and every battery will contribute the same amount of short circuit current to the ISCr once the ISCr happens. The ISCr battery could be identified by using the combination of the ratio and the sign of the short circuit currents. The battery pack based on individual DP (dual polarization) battery models is established to verify the ISCr detection method. The proposed ISCr detection method shows excellent effectiveness and efficiency on the identification of ISCr battery in the early stage, and hence provides sufficient time margin and safety margin to take countermeasures.
What problem does this paper attempt to address?