Are multiple projections necessary when assessing umbilical venous catheter placement in neonates? A retrospective study

Melanie Yeoh,Jonathan Erickson,Saumil Desai,Beth Hazeldine,Rebecca Thomas,Craig Gibson,Neil Powers,Nathalie Falkner
DOI: https://doi.org/10.1111/1754-9485.13632
2024-03-08
Journal of Medical Imaging and Radiation Oncology
Abstract:Introduction There is variability in clinical practice regarding the number of radiographic views required to accurately determine umbilical venous catheter (UVC) tip position. Some units prefer performing a single anteroposterior (AP) view and others do both AP and lateral views. The aim of this study was to compare the need for one versus two radiographical views to accurately determine UVC tip position. Methods Radiographs of 382 infants (all gestations) from two level six neonatal units were included in the study. Patients with congenital anomalies and those who had adjustment of UVC position between AP and lateral films being performed were excluded. Six clinicians reviewed anonymized AP only images and documented UVC tip position. Subsequently, they reviewed both AP and lateral views and again documented the UVC tip position. Results were compared to the expert consensus which was taken from the consensus of two paediatric radiologists. Results The study population had a mean gestational age of 32.8 weeks and birth weight of 2190 g, with 58% males. The UVC tip positions were accurately determined 76% times by the AP view alone and 82% times by using both the AP and lateral views (P
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?