Non-Contact Heart Rate Monitoring Method Based on Wi-Fi CSI Signal

Juncong Sun,Xin Bian,Mingqi Li
DOI: https://doi.org/10.3390/s24072111
IF: 3.9
2024-03-27
Sensors
Abstract:This paper introduces an innovative non-contact heart rate monitoring method based on Wi-Fi Channel State Information (CSI). This approach integrates both amplitude and phase information of the CSI signal through rotational projection, aiming to optimize the accuracy of heart rate estimation in home environments. We develop a frequency domain subcarrier selection algorithm based on Heartbeat to subcomponent ratio (HSR) and design a complete set of signal filtering and subcarrier selection processes to further enhance the accuracy of heart rate estimation. Heart rate estimation is conducted by combining the peak frequencies of multiple subcarriers. Extensive experimental validations demonstrate that our method exhibits exceptional performance under various environmental conditions. The experimental results show that our subcarrier selection method for heart rate estimation achieves an average accuracy of 96.8%, with a median error of only 0.8 bpm, representing an approximately 20% performance improvement over existing technologies.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve non - contact heart rate monitoring in a home environment. Traditional heart rate monitoring technologies mainly rely on wearable devices that directly contact the user's body. Although these devices have a certain guarantee in terms of monitoring accuracy, long - term wearing may cause discomfort to the user and are inconvenient in daily use. To overcome these problems, researchers have begun to explore non - contact health monitoring solutions, especially non - contact vital sign monitoring technologies. These technologies not only improve the user's comfort but also enhance the usability in the actual monitoring environment because they do not require the user's continuous participation. Specifically, this paper proposes a non - contact heart rate monitoring method based on Wi - Fi Channel State Information (CSI). This method integrates the amplitude and phase information of CSI signals through the rotation projection technique, aiming to optimize the accuracy of heart rate estimation in a home environment. In addition, the author has developed a frequency - domain sub - carrier selection algorithm based on the Heartbeat - to - Sub - component Ratio (HSR) and designed a whole set of signal filtering and sub - carrier selection processes to further improve the accuracy of heart rate estimation. By combining the peak frequencies of multiple sub - carriers for heart rate estimation, experimental verification shows that this method performs well under various environmental conditions, with an average accuracy rate of 96.8%, a median error of only 0.8 bpm, and a performance improvement of about 20% compared to existing technologies. In summary, the main contributions of this paper are as follows: 1. By using the rotation projection method, the amplitude and phase information of CSI signals are considered and integrated simultaneously, enhancing the sensing performance. 2. A sub - carrier selection algorithm based on frequency - domain indicators is proposed. Combined with the signal filtering and sub - carrier selection algorithm, the accuracy of heart rate estimation is improved. 3. Through extensive experimental tests, the performance of this method under different conditions is verified, showing higher accuracy and a wider detection range.