Membrane filtration as a pre-treatment method

Bernt Ericsson,Bengt Hallmans
DOI: https://doi.org/10.1016/0011-9164(91)85191-v
IF: 11.211
1991-08-01
Desalination
Abstract:Pre-treatment of raw water before reverse osmosis (RO) is of great importance for the economy and life of an RO plant. The extent of pre-treatment depends on the raw water quality. Conventional raw water treatment methods are normally used for pre-treatment in RO plants. The aim of this paper is to investigate the possibilities to use membrane methods, primarily ultrafiltration (UF), as alternatives for conventional pre-treatment stages. These methods are discussed from the point of view of both technical and economical competition with conventional methods including operation and maintenance.The cost calculations for RO plants with a capacity of 10,000 m3/d are based on available cost data from RO plants in operation in the Middle East. Different types of raw water are included in the cost comparison, viz. surface brackish water and seawater with worse quality than normal groundwater. The conventional pre-treatment stages, usually required before reverse osmosis, are discussed as well as the possibilities to replace some of these treatment stages with UF membrane filtration methods, and associated costs. This investigation shows the additional (differential) costs for the UF-RO plant as well as the prerequisites for UF-RO to be competitive with already established, conventional pre-treatment methods.
engineering, chemical,water resources
What problem does this paper attempt to address?