Endovascular repair for infra-renal aortic aneurysms with supra-renal fixation endoprosthesis: Results and outcomes

Rafael de Athayde Soares,Kaline Amaro,Ana Isabel Nasser,Marcus Vinícius Martins Cury,Edson Takamitsu Nakamura,Keityane de Lima Pedrosa,Roberto Sacilotto
DOI: https://doi.org/10.1177/17085381241264381
IF: 1.1
2024-07-20
Vascular
Abstract:Vascular, Ahead of Print. ObjectiveThe main objective of this paper is to evaluate the outcomes regarding endoleaks, reinterventions, and death related to aneurysm complications in patients submitted to endovascular repair (EVAR) for abdominal aortoiliac aneurysm (AAA) using Endurant II (Medtronic) and Zenith Flex (Cook) endografts.MethodsThis was a prospective, consecutive cohort study of patients with AAA who underwent EVAR with the use of Endurant II stent graft and Zenith Flex endograft.ResultsA total of 156 patients submitted to EVAR were evaluated. The perioperative mortality was 5.1%, 8 patients. The median clinical follow-up period was 760 ± 80 days. There were 28 patients (17.9%) submitted to urgent repair of the aneurysm (symptomatic expansion or rupture) and 128 patients (82.1%) submitted to elective repair. There were 36 cases (23.1%) of later endoleak and most of them are Type II endoleaks (21 patients, 13.4%). There were 12 cases of Type I endoleak. Moreover, regarding limb graft occlusion (LGO), there were 9 patients (5.8%). The overall survival rate in Kaplan–Meier analysis at 720 days was 84.8% in the total cohort. The freedom from reintervention rate in Kaplan–Meier analysis at 720 days was 92.7% in the total cohort. The linear regression analysis for survival rates showed that chronic kidney disease (p = .03; hazard ratio (HR) = 2.82, CI = 1.07–4.44) was the only factor related to poorer survival rates in both univariate and multivariate analyses. The linear regression analysis showed that the presence of endoleaks (p < .001, HR = 6.69, CI = 2.26–8.48) and limb graft occlusion (p < .001, HR = 8.02, CI = 1.60–9.99) were related to reintervention in both univariate and multivariate analyses.ConclusionIn this present study, supra-renal fixation endograft devices were safe and efficient in treating AAA, with satisfactory results and no renal compromise. The linear regression analysis showed that the presence of endoleaks and limb graft occlusion were related to higher reintervention rates in both univariate and multivariate analyses.
peripheral vascular disease
What problem does this paper attempt to address?