Abstract:Background Accurate gross tumor volume (GTV) delineation is a critical step in radiation therapy treatment planning. However, it is reader dependent and thus susceptible to intra- and inter-reader variability. GTV delineation of soft tissue sarcoma (STS) often relies on CT and MR images. Purpose This study investigates the potential role of 18 F-FDG PET in reducing intra- and inter-reader variability thereby improving reproducibility of GTV delineation in STS, without incurring additional costs or radiation exposure. Materials and Methods Three readers performed independent GTV delineation of 61 patients with STS using first CT and MR followed by CT, MR, and 18 F-FDG PET images. Each reader performed a total of six delineation trials, three trials per imaging modality group. Dice Similarity Coefficient (DSC) score and Hausdorff distance (HD) were used to assess both intra- and inter-reader variability using generated simultaneous truth and performance level estimation (STAPLE) GTVs as ground truth. Statistical analysis was performed using a Wilcoxon signed-ranked test. Results There was a statistically significant decrease in both intra- and inter-reader variability in GTV delineation using CT, MR 18 F-FDG PET images vs. CT and MR images. This was translated by an increase in the DSC score and a decrease in the HD for GTVs drawn from CT, MR and 18 F-FDG PET images vs. GTVs drawn from CT and MR for all readers and across all three trials. Conclusion Incorporation of 18 F-FDG PET into CT and MR images decreased intra- and inter-reader variability and subsequently increased reproducibility of GTV delineation in STS.
oncology,radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?