Ultrasensitive Nucleic Acid Assay Based on Cyclometalated Iridium(III) Complex with High Electrochemiluminescence Efficiency

Zhi-Hong Xu,Hang Gao,Nan Zhang,Wei Zhao,Yi-Xiang Cheng,Jing-Juan Xu,Hong-Yuan Chen
DOI: https://doi.org/10.1021/acs.analchem.0c04284
IF: 7.4
2020-12-30
Analytical Chemistry
Abstract:This work developed a sensitive electrochemiluminescence (ECL) biosensor based on a cyclometalated iridium(III) complex ((bt)<sub>2</sub>Irbza), which was synthesized for the first time. Annihilation, reductive–oxidative, and oxidative–reductive ECL behaviors of (bt)<sub>2</sub>Irbza were investigated, respectively. The oxidative–reductive ECL intensity was the strongest compared with the other two, which showed 16.7 times relative ECL efficiency compared with commercial [Ru(bpy)<sub>3</sub>]<sup>2+</sup> under the same experimental conditions. Therefore, an ECL biosensing system with (bt)<sub>2</sub>Irbza as the anodic luminophore was established for miRNA detection based on a closed bipolar electrode (BPE). Combined with both steric hindrance and catalytic effects induced by hemin/G-quadruplex in the cathodic reservoir of BPE that changed the Faraday current of the cathode and thus mediated the ECL intensity of (bt)<sub>2</sub>Irbza in the anode of BPE, the ECL sensor stated an ultrahigh sensitivity for microRNA (miRNA-122) analysis with a detection limit of 82 aM.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.0c04284?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.0c04284</a>.Reagents; apparatus; design and fabrication of closed BPE; <sup>1</sup>H NMR spectra of (bt)<sub>2</sub>Irbza; <sup>13</sup>C NMR spectra of (bt)<sub>2</sub>Irbza; mass spectra of (bt)<sub>2</sub>Irbza; phosphorescent lifetime of (bt)<sub>2</sub>Irbza; UV–vis absorption and fluorescence spectra of (bt)<sub>2</sub>Irbza; optimization of the concentration of BPO; cyclic voltammetry characterization of BPO; optimization of the concentration of TPrA; the ECL stability; optimization of the concentration of (bt)<sub>2</sub>Irbza and ECL intensity comparation; the spectra of photoluminescence and ECL; summarization of the experimental findings for (bt)<sub>2</sub>Irbza; comparison of the BPE–ECL biosensor and previous reports on miRNA detection; and specificity. (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c04284/suppl_file/ac0c04284_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?