An “Off−On” Electrochemiluminescent Biosensor Based on DNAzyme-Assisted Target Recycling and Rolling Circle Amplifications for Ultrasensitive Detection of microRNA
Pu Zhang,Y. Chai,Ruo Yuan,Xiaoya Wu
Abstract:In this study, an off−on switching of a dual amplified electrochemiluminescence (ECL) biosensor based on Pb-induced DNAzyme-assisted target recycling and rolling circle amplification (RCA) was constructed for microRNA (miRNA) detection. First, the primer probe with assistant probe and miRNA formed Y junction which was cleaved with the addition of Pb to release miRNA. Subsequently, the released miRNA could initiate the next recycling process, leading to the generation of numerous intermediate DNA sequences (S2). Afterward, bare glassy carbon electrode (GCE) was immersed into HAuCl4 solution to electrodeposit a Au nanoparticle layer (depAu), followed by the assembly of a hairpin probe (HP). Then, dopamine (DA)modified DNA sequence (S1) was employed to hybridize with HP, which switching off the sensing system. This is the first work that employs DA to quench luminol ECL signal, possessing the biosensor ultralow background signal. Afterward, S2 produced by the target recycling process was loaded onto the prepared electrode to displace S1 and served as an initiator for RCA. With rational design, numerous repeated DNA sequences coupling with hemin to form hemin/G-quadruplex were generated, which could exhibit strongly catalytic toward H2O2, thus amplified the ECL signal and switched the ON state of the sensing system. The liner range for miRNA detection was from 1.0 fM to 100 pM with a low detection limit down to 0.3 fM. Moreover, with the high sensitivity and specificity induced by the dual signal amplification, the proposed miRNA biosensor holds great potential for analysis of other interesting tumor markers. M (miRNA) are a fresh emerging series of endogenetic, small, noncoding single-stranded RNAs, primarily functioning as significant regulators to regulate fundamental cellular procedures via the modulation toward the expression of target genes. Until now, various analytical methods, including electrochemical, fluorescent, chemiluminescent, electrochemiluminescence (ECL), and surface plasmon resonance, have been implemented to realize sensitive detection of miRNA. Among these protocols, ECL, because of its rapidness, high detection sensitivity, simplified operation, and low cost, has attracted particular attention and offered new opportunities for applications in biological analysis. In ECL system, the target recycling amplification techniques related to nicking-nuclease have been regarded as the most frequently used methods, such as nicking endonuclease signal amplification and exonuclease III-aided signal amplification. Nevertheless, these amplified strategies suffered from negative factors, involving high cost and possible false responses, because of the inactivation of the enzyme. Leadrequiring DNAzyme is a sequence-specific nuclease that can catalyze a wide succession of biological and biochemical reactions, which could smooth over the above disadvantages. Lead-requiring DNAzyme has received remarkable interests, because of its merits of high sensitivity, easy operation, low cost to produce, and ability to be renatured many times without losing activity. Such a lead-requiring DNAzyme compound have been isolated in test tubes and is highly affinitive for specific metal ions, including Pb(II), Cu(II), and Zn(II). A typical Pb-requiring DNAzyme design called “8-17” is composed of a substrate strand (17DS) and an enzyme strand (17E). In the presence of Pb, the specific cleavage of substrate strand was nicked, resulting in the substrate strand changing into two fragments. To the best of our knowledge, there is little research that focuses on adapting a Pb-lead dependent DNAzyme in an ECL biosensor for miRNA detection. As one of the most extensively implicated luminophores in ECL, luminol has some outstanding properties, including nontoxicity, low oxidation, moderate price, and high lightemitting quantum yield. The luminol ECL response could be increased by the presence of H2O2, since the decomposition of H2O2 may generate a large number of reactive oxygen Received: September 1, 2014 Accepted: February 13, 2015 Published: February 13, 2015 Article
Chemistry,Biology