FAILURE FOLLOWING INTERNAL FIXATION OF SPINE:CAUSES AND COUNTERMEASURES

L. Lei
Abstract:Objective To analyze the causes of failure in internal fixation of spine,and explore measures to avoid it.Methods From January 2010 to December 2011,2 200 patients underwent spinal-internal-fixation in our department.Of whom,1 350 were completely followed and their clinical data analyzed retrospectively.Results Failures of internal fixation were found in 35 patients.The causes observed were as follows: loosening and shifting of anterior cervical locking screw-plate device(four cases),broken of posterior cervical plate(five),loosening of posterior cervical lateral mass screw(five),loosening of pedicle screw(nine),broken of pedicle screw(five),nerve root was excited due to unfit location of the screw(four) and infection(three).The manifestations were deformity,localized pain,abnormal sound,limb numbness or pain,or fever.Conclusion The main causes of failure of spine internal fixation operation include unskilled surgical technique,incomprehension of biomechanical concept,insufficient decortication of bone graft bed,no enough bone graft,and others such as infection,osteoporosis and ill-suited internal fixation devices.
Medicine