Design and experiment results of HL-3 baking system

Y.J. Bai,Y.F. Xie,R.B. Jia,Q. Cai,J.P. Meng,L.Y. Qiu,J.Q. Wang,M. Li,X.Y. Gao,Y. Lu,X.L. Liu
DOI: https://doi.org/10.1016/j.fusengdes.2024.114619
IF: 1.905
2024-08-19
Fusion Engineering and Design
Abstract:HL-3 is a tokamak device constructed in 2020 and it has achieved remarkable results in a short period of time. Baking is an important way to obtain a high vacuum required for plasma discharge in tokamak devices. A nitrogen gas closed-circuit reheat baking system is utilized to concurrently bake the vacuum vessel (VV) and the lower divertor of HL-3. So far, three rounds of baking experiments have been carried out, with vacuum pressure up to 1.8 × 10 –6 Pa and the results from the mass spectrometer indicated that the amount of compounds were greatly reduced in the residual gas. Besides the design description and experimental results of HL-3 baking system, this paper also introduces a simulation-based solution for addressing the issue of the lower divertor temperature being significantly lower than that of the VV after baking to the high temperature stage.