Green and sustainable method of manufacturing anti-fouling zwitterionic polymers-modified poly(vinyl chloride) ultrafiltration membranes

Wancen Xie,Alberto Tiraferri,Xuanyu Ji,Chen Chen,Yuhua Bai,John C Crittenden,Baicang Liu,John C. Crittenden
DOI: https://doi.org/10.1016/j.jcis.2021.01.107
IF: 9.9
2021-06-01
Journal of Colloid and Interface Science
Abstract:<p>The nonsolvent induced phase separation (NIPS) method for ultrafiltration (UF) membrane fabrication relies on the extensive use of traditional solvents and toxic chemicals, thus ranking first in terms of ecological impacts among all the membrane fabrication steps. Methyl-5-(dimethylamino)-2-methyl-5-oxopentanoate (PolarClean), as a green solvent, was utilized in this study to fabricate poly(vinyl chloride) (PVC) UF membranes. Subsequently, in post-treatment process, zwitterionic polymer, [2-(methacryloyloxy) ethyl] dimethyl-(3-sulfopropyl) ammonium hydroxide (DMAPS), was grafted onto the membrane surface to enhance its anti-fouling properties using a greener surface-initiated activator regenerated by electron transfer-atom transfer radical polymerization (ARGET-ATRP) reaction. This novel method used low toxicity chemicals, avoiding the environmental hazards of traditional ATRP, and greatly improving the reaction efficiency. We systematically studied the grafting time effect on the resulted membranes using sodium alginate as the foulant, and found that short grafting time (30 minutes) achieved excellent membrane performance: pure water permeability of 2872 L m<sup>−2</sup> h<sup>−1</sup> bar<sup>−1</sup>, flux recovery ratio of 86.4 % after 7-hour fouling test, and foulant rejection of 96.0 %. This work discusses for the first time the greener procedures with lower environmental impacts in both fabrication and modification processes of PVC UF membranes.</p>
chemistry, physical
What problem does this paper attempt to address?
This paper attempts to solve the following problems: 1. **Environmental impacts in the traditional ultra - filtration membrane manufacturing process**: The traditional non - solvent - induced phase separation (NIPS) method relies on the use of a large amount of traditional organic solvents in the manufacturing of ultra - filtration (UF) membranes, and these solvents are harmful to the environment and human health. Therefore, the paper proposes to use the green solvent PolarClean to replace traditional solvents to reduce environmental impacts. 2. **Insufficient anti - fouling performance of polyvinyl chloride (PVC) ultra - filtration membranes**: Due to its inherent hydrophobicity, PVC membranes are prone to fouling, resulting in a decrease in flux and a shortened service life. To solve this problem, the paper grafts the zwitterionic polymer [2 - (methacryloyloxy)ethyl]dimethyl - (3 - sulfopropyl)ammonium hydroxide (DMAPS) on the surface to improve the hydrophilicity and anti - fouling performance of PVC membranes. 3. **Developing more environmentally - friendly surface modification methods**: Traditional atom transfer radical polymerization (ATRP) reactions require the use of toxic chemicals and have harsh reaction conditions. The paper adopts a more environmentally - friendly surface - initiated electron - transfer - atom - transfer radical polymerization (ARGET - ATRP) method, which uses a lower catalyst concentration, has mild reaction conditions, and reduces environmental harm. ### Main research contents - **Application of green solvents**: Using PolarClean as a green solvent to prepare PVC ultra - filtration membranes reduces the use of traditional solvents and environmental pollution. - **Grafting of zwitterionic polymers**: DMAPS is grafted onto the surface of PVC membranes by the ARGET - ATRP method to enhance the anti - fouling performance of the membranes. Research shows that a relatively short grafting time (30 minutes) can significantly improve the performance of the membranes, including pure water flux, flux recovery rate, and contaminant rejection rate. - **Optimization of reaction conditions**: The influence of grafting time on the grafting effect is systematically studied, and it is found that a grafting time of 30 minutes can achieve the best membrane performance, while an overly long grafting time will lead to an increase in the surface roughness of the membrane, which is not conducive to anti - fouling performance instead. ### Experimental results - **Morphology and chemical composition of the membrane**: SEM and AFM images show that as the grafting time increases, the pore size and porosity of the membrane gradually decrease, indicating an increase in the thickness of the DMAPS brush layer and the grafting density. XPS and FTIR analyses confirm the successful grafting of DMAPS. - **Hydrophilicity and anti - fouling performance**: After grafting DMAPS, the water contact angle of the membrane is significantly reduced, and the hydrophilicity is enhanced. The anti - fouling performance is also significantly improved, especially when the grafting time is 30 minutes, the flux recovery rate reaches 86.4%. - **Analysis of interfacial free energy**: The interfacial free energy between the membrane and the contaminant is calculated by the extended DLVO theory to further verify the effectiveness of the DMAPS brush layer. The results show that the interaction energy between the grafted membrane and the contaminant is significantly weakened, thereby improving the anti - fouling performance. ### Conclusion This study has successfully developed a green and sustainable method to manufacture PVC ultra - filtration membranes with excellent anti - fouling performance. By using the green solvent PolarClean and the environmentally - friendly ARGET - ATRP method, not only the environmental impact is reduced, but also the performance of the membrane is significantly improved. In particular, a relatively short grafting time (30 minutes) can achieve the ideal anti - fouling effect, providing strong support for practical applications.