Pitfalls of a commonly used accelerated stress test for reversal tolerance testing of proton exchange membrane fuel cell anode layers

Ye Peng,Ja-Yeon Choi,Kyoung Bai,Liliang Tian,Katie Pei,Yi Zhang,Dustin Banham
DOI: https://doi.org/10.1016/j.jpowsour.2024.234087
IF: 9.2
2024-01-26
Journal of Power Sources
Abstract:Anode reversal occurs in proton exchange membrane fuel cells (PEMFCs) when one or several membrane electrode assemblies (MEAs) in a stack experience global hydrogen starvation, causing the anode potential to reach values > 1.5 V leading to rapid carbon corrosion and eventually catastrophic failure of the MEA. To mitigate this, a common solution has been to add an anti-reversal catalyst (ARC) into the anode which can promote water oxidation in favor of carbon corrosion. The most common accelerated stress test (AST) for evaluating new ARCs in single-cell MEAs has been a galvanostatic test whereby a constant current is applied to the MEA while air/N 2 are used for the cathode/anode gas streams. Less commonly, another AST that has been used is a pulsing experiment whereby the anode is cycled between normal operating conditions and reversal conditions. These two types of ASTs have both been used in the literature for determining the durability of ARCs and novel anode design concepts. Here, by directly comparing two well known ARCs, one with high stability (IrO x ) and one with low stability (RuO x ), it is shown that the less commonly used pulsing AST provides a more comprehensive gauge of anode durability during reversal events.
energy & fuels,materials science, multidisciplinary,electrochemistry,chemistry, physical
What problem does this paper attempt to address?